R88M-W75030T-S1 Omron, R88M-W75030T-S1 Datasheet - Page 202

no-image

R88M-W75030T-S1

Manufacturer Part Number
R88M-W75030T-S1
Description
SERVO MOTOR 750W 200V
Manufacturer
Omron
Datasheet

Specifications of R88M-W75030T-S1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MW75030TS1
• Code Display
• Codes are displayed one character at a time on the Servo Driver's front panel display, as shown
4-2-2 Absolute Encoder Setup and Battery Changes
The absolute encoder's multi-turn data may become too large when connecting the Servomotor to
the mechanical system for trial operation, so the setup must be executed again.
The setup must be executed again if an alarm (A.810) occurs after the Battery Unit has been
replaced.
4-6
Operation
below.
During Trial Operation
When Replacing the Battery Unit
Status display
Status display
Code
Cases where Setup is Required
@@
Example:When both forward rotation drive prohibit (P) and reverse rotation drive prohibit (n) are
Example:A.E60
(bit data)
(bit data)
Status display
You must set up the absolute encoder if using a Servomotor with an absolute encoder.
Perform the setup if connecting a Battery Unit (R88A-BAT01W) to an absolute encoder
for the first time, or when setting the mechanical rotation data to 0 for a trial operation.
For the absolute encoder setup, refer to Computer Monitor Software procedure.
Forward rotation drive prohibited (POT is OFF) or
the forward software limit has been exceeded.
Reverse rotation drive prohibited (NOT is OFF) or
the reverse software limit has been exceeded.
Alarm display (Refer to 5-2 Alarms.)
ON:
Not lit
Not lit
Not lit
Code display
Not lit
Details
Not lit
Not lit
Not lit
Not lit
Chapter 4