5-16
Troubleshooting
a.100
Display
Overcurrent or
overheating of
radiation shield
Error
Occurs when main
circuit power sup-
ply is turned ON,
or when an over-
current occurs dur-
ing Servomotor
operation.
Status when
error occurs
• The DB has frequent use.
• An overload alarm has
• Was the load excessive,
• The Servo Driver was
• The Servo Driver's fan is
• Servo Driver is defective. • Replace the Servo
(A DB overload alarm
occurred.)
been reset several times
by turning OFF the
power.
or was the regeneration
processing capacity
exceeded?
mounted in an unsuit-
able way (direction, spac-
ing). (Is there heat
radiation in the or is there
a heating effect from the
surroundings?)
stopped.
Cause of error
• Replace the Servo
• Change the alarm reset
• Recheck the load and
• Reduce the Servo
• Replace the Servo
Driver.
(Reduce the frequency of
DB use.)
method.
operating conditions.
Driver's ambient temper-
ature to 55 ° C or below.
Driver.
Driver.
Countermeasures
Chapter 5