If vibration thought to be caused by the Servo Driver occurs in the machinery, adjusting the torque
command filter time constant may cause the vibration to subside. The lower the value is set, the bet-
ter the response of the control that can be achieved. There are limits, however, depending on the
conditions of the machinery.
Note The unit for the 3rd step torque command filter time constant is different from the units for the
• A notch filter can be set for internal torque commands (commands to the current loop). A notch filter
• If mechanical resonance is occurring, a notch filter can be used to prevent it. This makes it possible
• With W-series AC Servo Drivers, two notch filters (notch filters 1 and 2) can be set.
Note This is a filter setting for the purpose of preventing machine resonance that cannot be elimi-
4-124
Operation
Pn401
Pn40F
Pn410
Pn411
is a function for lowering the response of the frequency that is set. The degree to which the
response is to be lowered is set by the Q value.
to shorten positioning time by raising the speed loop gain.
Functions
Parameters Requiring Settings
Functions
Parameter
Torque Command Filter
Notch Filter
No.
step 1 and step 2. The 2nd step 2nd torque command filter will be disabled if Pn40F (2nd step
2nd torque command filter frequency) is set to 2,000 Hz.
nated by simply adjusting the gain. If it not set carefully, it may have the unintended effect of
making machine operation unstable. Adjust the setting while monitoring machine operation by
means such as the torque command monitor. Also, provide an emergency stop switch that can
be pressed to immediately stop the machinery.
1st step 1st torque
command filter time
constant
2nd step 2nd torque
command filter fre-
quency
2nd step 2nd torque
command filter Q value
3rd step torque com-
mand filter time con-
stant
Parameter name
Set the step 1 torque time constant for the
torque command.
Setting range: 0 to 65,535 ( × 0.01 ms)
When using the 2nd step 2nd torque command
filter frequency, set a number other than
2,000 Hz.
Setting range: 100 to 2,000 (Hz)
Set the 2nd step 2nd torque command filter Q
value.
Setting range: 50 to 1,000 ( × 0.01)
Set the 3rd step torque command filter time
constant.
Setting range: 0 to 65,535 ( µ s)
Explanation
4-3-3 Parameter
Details
4-3-3 Parameter
Details
4-3-3 Parameter
Details
4-3-3 Parameter
Details