MK30DN512ZVLK10 Freescale Semiconductor, MK30DN512ZVLK10 Datasheet - Page 484

no-image

MK30DN512ZVLK10

Manufacturer Part Number
MK30DN512ZVLK10
Description
ARM Microcontrollers - MCU KINETIS 512K SLCD
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MK30DN512ZVLK10

Core
ARM Cortex M4
Processor Series
K30
Data Bus Width
32 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
512 KB
Data Ram Size
128 KB
On-chip Adc
Yes
Operating Supply Voltage
1.71 V to 3.6 V
Operating Temperature Range
- 40 C to + 105 C
Package / Case
LQFP-80
Mounting Style
SMD/SMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MK30DN512ZVLK10
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Functional Description
22.4.2 The EWM_in Signal
The EWM_in is a digital input signal that allows an external circuit to control the
EWM_out signal. For example, in the application, an external circuit monitors a critical
safety function, and if there is fault with this circuit's behavior, it can then actively initiate
the EWM_out signal that controls the gating circuit.
The EWM_in signal is ignored if the EWM is disabled, or if INEN bit of CTRL register
is cleared, as after any reset.
On enabling the EWM (setting the CTRL[EWMEN] bit) and enabling EWM_in
functionality (setting the CTRL[INEN] bit), the EWM_in signal must be in the deasserted
state prior to the CPU servicing the EWM. This ensures that the EWM_out stays in the
deasserted state; otherwise, the EWM_out pin is asserted.
22.4.3 EWM Counter
It is an 8-bit ripple counter fed from a clock source that is independent of the peripheral
bus clock source. As the preferred time-out is between 1 ms and 100 ms the actual clock
source should be in the kHz range.
The counter is reset to zero, after a CPU reset, or a EWM refresh cycle. The counter
value is not accessible to the CPU.
22.4.4 EWM Compare Registers
The compare registers CMPL and CMPH are write-once after a CPU reset and cannot be
modified until another CPU reset occurs.
484
EWM_out pad must be in pull down state when EWM
functionality is used and when EWM is under Reset.
You must update the CMPH and CMPL registers prior to
enabling the EWM. After enabling the EWM, the counter resets
to zero, therefore providing a reasonable time after a power-on
reset for the external monitoring circuit to stabilize and ensure
that the EWM_in pin is deasserted.
K30 Sub-Family Reference Manual, Rev. 6, Nov 2011
Note
Note
Freescale Semiconductor, Inc.

Related parts for MK30DN512ZVLK10