MK30DN512ZVLK10 Freescale Semiconductor, MK30DN512ZVLK10 Datasheet - Page 927

no-image

MK30DN512ZVLK10

Manufacturer Part Number
MK30DN512ZVLK10
Description
ARM Microcontrollers - MCU KINETIS 512K SLCD
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MK30DN512ZVLK10

Core
ARM Cortex M4
Processor Series
K30
Data Bus Width
32 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
512 KB
Data Ram Size
128 KB
On-chip Adc
Yes
Operating Supply Voltage
1.71 V to 3.6 V
Operating Temperature Range
- 40 C to + 105 C
Package / Case
LQFP-80
Mounting Style
SMD/SMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MK30DN512ZVLK10
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
37.4 Functional Description
This section provides the functional description of the module.
37.4.1 General
This section gives detailed information on the internal operation of the module. Each
timer can be used to generate trigger pulses as well as to generate interrupts. Each
interrupt is available on a separate interrupt line.
37.4.1.1 Timers
The timers generate triggers at periodic intervals, when enabled. They load their start
values, as specified in their LDVAL registers, then count down until they reach 0. Then
they load their respective start value again. Each time a timer reaches 0, it will generate a
trigger pulse and set the interrupt flag.
All interrupts can be enabled or masked (by setting the TIE bits in the TCTRL registers).
A new interrupt can be generated only after the previous one is cleared.
If desired, the current counter value of the timer can be read via the CVAL registers.
The counter period can be restarted, by first disabling, then enabling the timer with the
TEN bit (see the following figure).
Freescale Semiconductor, Inc.
Reserved
31–1
Field
TIF
0
This read-only field is reserved and always has the value zero.
Timer Interrupt Flag.
TIF is set to 1 at the end of the timer period. This flag can be cleared only by writing it with 1. Writing 0
has no effect. If enabled (TIE = 1), TIF causes an interrupt request.
0
1
Time-out has not yet occurred.
Time-out has occurred.
K30 Sub-Family Reference Manual, Rev. 6, Nov 2011
PIT_TFLGn field descriptions
Description
Chapter 37 Periodic Interrupt Timer (PIT)
927