MK30DN512ZVLK10 Freescale Semiconductor, MK30DN512ZVLK10 Datasheet - Page 916

no-image

MK30DN512ZVLK10

Manufacturer Part Number
MK30DN512ZVLK10
Description
ARM Microcontrollers - MCU KINETIS 512K SLCD
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MK30DN512ZVLK10

Core
ARM Cortex M4
Processor Series
K30
Data Bus Width
32 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
512 KB
Data Ram Size
128 KB
On-chip Adc
Yes
Operating Supply Voltage
1.71 V to 3.6 V
Operating Temperature Range
- 40 C to + 105 C
Package / Case
LQFP-80
Mounting Style
SMD/SMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MK30DN512ZVLK10
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Reset Overview
In the configuration described in the preceding figure, FTM modules A and B have their
FTM counters enabled if at least one of the gtb_out signals from one of the FTM modules
is 1. There are several possible configurations for the interconnection of the gtb_in and
gtb_out signals (represented by the example glue logic shown in the figure). Note that
these configurations are chip-dependent and implemented outside of the FTM modules.
See the Chip Configuration details for the chip's specific implementation.
36.4.28.1 Enabling the global time base (GTB)
To enable the GTB feature, follow these steps for each participating FTM module:
To initiate the GTB feature, follow these steps for the FTM module used as the time base:
36.5 Reset Overview
The FTM is reset whenever any chip reset occurs.
916
1. Stop the FTM counter: Write 00b to SC[CLKS].
2. Program the FTM module to the intended configuration. (The operation mode needs
3. Write 1 to CONF[GTBEEN] and write 0 to CONF[GTBEOUT] at the same time.
4. Select the intended FTM counter clock source in SC[CLKS]. (The clock source
5. Reset the FTM counter: Write any value to the CNT register.
1. Write 1 to CONF[GTBEOUT].
2. If needed, configure the GTB glue logic connecting the FTM modules within the
to be consistent across all participating modules.)
needs to be consistent across all participating modules.)
chip. Some chips do not require configuration of glue logic. See the Chip
Configuration details for the chip's specific implementation.
• In order to use the internal GTB signals to synchronize the
• The GTB feature does not provide continuous
FTM counter of different FTM modules, the configuration
of each FTM module should guarantee that its FTM
counter starts counting as soon as the gtb_in signal is 1.
synchronization of FTM counters, meaning that the FTM
counters may lose synchronization during FTM operation.
The GTB feature only allows the FTM counters to start
their operation synchronously.
K30 Sub-Family Reference Manual, Rev. 6, Nov 2011
NOTE
Freescale Semiconductor, Inc.