D12674RVFQ33D Renesas Electronics America, D12674RVFQ33D Datasheet - Page 133

MCU 3V 0K I-TEMP 144-QFP

D12674RVFQ33D

Manufacturer Part Number
D12674RVFQ33D
Description
MCU 3V 0K I-TEMP 144-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2600r
Datasheet

Specifications of D12674RVFQ33D

Core Processor
H8S/2600
Core Size
16-Bit
Speed
33MHz
Connectivity
IrDA, SCI
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
103
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 4x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Other names
HD6412674RVFQ33D
HD6412674RVFQ33D

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12674RVFQ33DV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
The interrupt exception handling is as follows:
1. The values in the program counter (PC), condition code register (CCR), and extended register
2. The interrupt mask bit is updated and the T bit is cleared to 0.
3. A vector address corresponding to the interrupt source is generated, the start address is loaded
4.6
Trap instruction exception handling starts when a TRAPA instruction is executed. Trap instruction
exception handling can be executed at all times in the program execution state.
The trap instruction exception handling is as follows:
1. The values in the program counter (PC), condition code register (CCR), and extended register
2. The interrupt mask bit is updated and the T bit is cleared to 0.
3. A vector address corresponding to the interrupt source is generated, the start address is loaded
The TRAPA instruction fetches a start address from a vector table entry corresponding to a vector
number from 0 to 3, as specified in the instruction code.
Table 4.4 shows the status of CCR and EXR after execution of trap instruction exception handling.
Table 4.4
Legend:
1:
0:
—: Retains value prior to execution.
(EXR) are saved in the stack.
from the vector table to the PC, and program execution starts from that address.
(EXR) are saved in the stack.
from the vector table to the PC, and program execution starts from that address.
Set to 1
Cleared to 0
Interrupt Control Mode
Trap Instruction
Status of CCR and EXR after Trap Instruction Exception Handling
0
2
1
1
I
CCR
UI
Rev. 3.00 Mar 17, 2006 page 81 of 926
Section 4 Exception Handling
I2 to I0
REJ09B0283-0300
EXR
T
0