HD64F3029XBL25V Renesas Electronics America, HD64F3029XBL25V Datasheet - Page 518

MCU 5V 512K,PB-FREE 100-TQFP

HD64F3029XBL25V

Manufacturer Part Number
HD64F3029XBL25V
Description
MCU 5V 512K,PB-FREE 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheet

Specifications of HD64F3029XBL25V

Core Processor
H8/300H
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, PWM, WDT
Number Of I /o
70
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Figure 13.4 shows a sample flowchart for initializing the SCI.
Note: In simultaneous transmitting and receiving, the TE and RE bits should be cleared to
Set CKE1 and CKE0 bits in SCR
Select communication format
Set TE or RE bit to 1 in SCR
Set the RIE, TIE, TEIE, and
(leaving TE and RE bits
Clear TE and RE bits
1-bit interval elapsed?
<End of initialization>
0 or set to 1 simultaneously.
Start of initialization
Set value in BRR
cleared to 0)
to 0 in SCR
MPIE bits
in SMR
Figure 13.4 Sample Flowchart for SCI Initialization
Yes
Wait
No
(1)
(2)
(3)
(4)
(1)
(2)
(3)
(4)
Set the clock source in SCR. Clear the
RIE, TIE, TEIE, MPIE, TE, and RE bits to
0. If clock output is selected in asynchro-
nous mode, clock output starts immedi-
ately after the setting is made in SCR.
Select the communication format in SMR.
Write the value corresponding to the bit
rate in BRR.
This step is not necessary when an
external clock is used.
Wait for at least the interval required to
transmit or receive one bit, then set the
TE or RE bit to 1 in SCR. Set the RIE,
TIE, TEIE, and MPIE bits as necessary.
Setting the TE or RE bit enables the SCI
to use the TxD or RxD pin.
Rev. 2.0, 06/04, page 489 of 980

Related parts for HD64F3029XBL25V