System Design and Installation
• Use ground lines with a minimum thickness of 3.5 mm
• If no-fuse breakers are installed at the top and the power supply line is wired from the lower duct, use
• No-fuse breakers, surge absorbers, and noise filters (NF) should be positioned near the input terminal
• If surge absorbers are installed, incorporate a fuse to protect against short-circuit failure. As a guide,
• Wire the noise filter as shown at the left in the following illustration. The noise filter should be installed
• Use twisted-pair cables for the power supply cables whenever possible, or bind the cables.
• Separate power supply cables and signal cables when wiring.
H Selecting Components
are as short as possible.
metal tubes for wiring and make sure that there is adequate distance between the input lines and the
internal wiring. If input and output lines are wired together, noise resistance will decrease.
block (ground plate), and I/O lines should be isolated and wired using the shortest distance possible.
select a fuse with approximately three times the maximum momentary current.
at the entrance to the control box whenever possible.
This section explains the criteria for selecting the connection components required for
improving noise resistance. These criteria include capacity performance, applicable
range, and so on. For more details, contact the manufacturers directly.
Correct: Properly twisted
Correct: Separate input and output
AC input
Ground
Driver
AC output
or
2
, and arrange the wiring so that the ground lines
WRONG: Noise not filtered effectively
AC output
Binding
AC input
Correct: Cables are bound.
Ground
Driver
Chapter 3
3-21