R88M-WP10030S-BWS1 Omron, R88M-WP10030S-BWS1 Datasheet - Page 386

no-image

R88M-WP10030S-BWS1

Manufacturer Part Number
R88M-WP10030S-BWS1
Description
SERVO MOTOR 100W 100V W/BRAKE
Manufacturer
Omron
Datasheet

Specifications of R88M-WP10030S-BWS1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MWP10030SBWS1
Operation
4-11-8 Password Setting
H Password Setting (Fn010)
• This function prevents the user parameter settings and System Check Mode settings and adjustments
• When a write-prohibited password is set, from the next power-up onwards it becomes impossible to
If you try to perform any functions other than these, “nO OP” will flash for approximately 1 s, and then the
display will return to the function code.
• If you set the write-enabled password, the write-prohibited status will be cancelled (i.e., you can write
4-148
being overwritten unintentionally.
make parameter settings or to make settings or adjustments in System Check Mode. It still remains
possible, however, to refer to the user parameters and perform some functions in System Check
Mode. The functions that can be performed in System Check Mode while write prohibited is enabled
are as follows:
to the user parameters, etc., when the power is next turned ON again).
System Check Mode
Password setting
Display alarm log (Fn000), password setting (Fn010), Servomotor parameters check (Fn011), and
version check (Fn012).
1 s min.
1 s min.
(1 s later)
Password display
Password display
“donE” flashes (password setting
completed)
Return to password
display
Write to password
Chapter 4

Related parts for R88M-WP10030S-BWS1