Note This new parameter is supported by Servo Drivers with software version “r.0037.”
H Other Parameters (From Pn600)
• If using an External Regeneration Resistor or External Regeneration Resistance Unit, set the regen-
• Perform Un00A (regeneration load monitor) calculations, and A.92 (regeneration overload warning)
Note If an External Regeneration Resistor or External Regeneration Resistance Unit is not connected,
Note Do not change the setting.
Pn600
Setting
range
Pn601
Setting
range
• Set the deviation counter overflow warning detection level using the ratio (%) for Pn505 (deviation
• When the deviation counter residual pulses exceed the set value, a deviation counter overflow warn-
• When the set value is 0, the deviation counter overflow warning will not be detected.
eration absorption amount. Set the regeneration absorption amount for when the temperature rises
above 120°C, not the nominal amount. (Refer to Regenerative Energy Absorption Using External Re-
generation Resistance for details.)
and A.32 (regeneration overload alarm) based on the Pn600 setting.
counter overflow level).
ing (A.90) will occur.
set Pn600 to 0.
Regeneration resistor capacity
0 to Unit
type
Not used.
---
Unit
Unit
x 10 W
---
Default
setting
Default
setting
0
0
Restart
power?
Restart
power?
Chapter 4
No
No
4-71