R88M-WP10030S-BWS1 Omron, R88M-WP10030S-BWS1 Datasheet - Page 9

no-image

R88M-WP10030S-BWS1

Manufacturer Part Number
R88M-WP10030S-BWS1
Description
SERVO MOTOR 100W 100V W/BRAKE
Manufacturer
Omron
Datasheet

Specifications of R88M-WP10030S-BWS1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MWP10030SBWS1
Operation and Adjustment Precautions
!
!
!
!
!
!
!
!
!
!
!
!
Caution
Caution
Caution
Caution
Caution
Caution
Caution
Caution
Caution
Caution
Caution
Caution
Take appropriate measures to ensure that the specified power with the rated voltage
and frequency is supplied. Be particularly careful in places where the power supply
is unstable. An incorrect power supply may result in malfunction.
Install external breakers and take other safety measures against short-circuiting in
external wiring. Insufficient safety measures against short-circuiting may result in
burning.
Provide an appropriate stopping device on the machine side to secure safety. (A
holding brake is not a stopping device for securing safety.) Not doing so may result in
injury.
Provide an external emergency stopping device that allows an instantaneous stop of
operation and power interruption. Not doing so may result in injury.
Take appropriate and sufficient countermeasures when installing systems in the fol-
lowing locations:
S Locations subject to static electricity or other forms of noise.
S Locations subject to strong electromagnetic fields and magnetic fields.
S Locations subject to possible exposure to radioactivity.
S Locations close to power supplies.
Do not reverse the polarity of the battery when connecting it. Reversing the polarity
may damage the battery or cause it to explode.
Confirm that no adverse effects will occur in the system before performing the test
operation. Not doing so may result in equipment damage.
Confirm that no adverse effects will occur in the system before performing the test
operation. Not doing so may result in equipment damage.
Check the newly set parameters for proper execution before actually running them.
Not doing so may result in equipment damage.
Do not make any extreme adjustments or setting changes. Doing so may result in
unstable operation and injury.
Separate the Servomotor from the machine, check for proper operation, and then
connect to the machine. Not doing so may cause injury.
When an alarm occurs, remove the cause, reset the alarm after confirming safety,
and then resume operation. Not doing so may result in injury.