R88M-WP10030S-BWS1 Omron, R88M-WP10030S-BWS1 Datasheet - Page 359

no-image

R88M-WP10030S-BWS1

Manufacturer Part Number
R88M-WP10030S-BWS1
Description
SERVO MOTOR 100W 100V W/BRAKE
Manufacturer
Omron
Datasheet

Specifications of R88M-WP10030S-BWS1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MWP10030SBWS1
Operation
H Bit Data Display Contents
H Symbol Display Contents
Control-circuit power supply ON
Main-circuit power supply ON
Base block
Positioning completed 1
Speed conformity
Rotation detection
Inputting command pulses
Inputting speed command
Inputting deviation counter reset
signal
Inputting torque command
Symbol display
Positioning completed 1
(during position control)
Speed conformity
(during speed control)
Bit data
Control-circuit
power supply ON
Base block
Base block (no power to Servomotor, servo is OFF)
Operating (power to Servomotor, servo is ON)
Forward rotation prohibited (POT (Forward rotation prohibited input) is OFF)
Reverse rotation prohibited (NOT (Reverse rotation prohibited input) is OFF)
Alarm display (Refer to alarm table.)
Key operation disabled (When attempting to execute operations that cannot be
performed in System Check Mode)
Setting error (When a parameter setting is not suitable)
Lit when Servo Driver control-circuit power supply is ON.
Lit when Servo Driver main-circuit power supply is ON.
Lit during base block (no power to Servomotor, servo is OFF); dimmed
when servo is ON.
Lit when the residual pulses in the deviation counter fall below the set-
ting for Pn500 (positioning completion range 1).
Lit when the Servomotor rotation speed is within the range of (speed
command value ± (Pn503 (speed conformity signal output width)).
Lit when the Servomotor rotation speed is equal to or greater than
Pn502 (rotation speed for motor rotation detection) setting.
Lit when command pulses are being input.
Lit when a speed command input meets or is greater than Pn502 (rota-
tion speed for motor rotation detection) setting.
Lit when the ECRST (deviation counter reset signal) is being input.
Lit when a torque command at least 10% of the rated torque is input.
Deviation counter reset signal being input (position control)
Torque commands being input (torque control)
Rotation detected
Main-circuit power supply ON
Contents
Command pulses being input
(during position control)
Speed commands being input
(during position control)
Contents
Chapter 4
4-121