R88M-WP10030S-BWS1 Omron, R88M-WP10030S-BWS1 Datasheet - Page 224

no-image

R88M-WP10030S-BWS1

Manufacturer Part Number
R88M-WP10030S-BWS1
Description
SERVO MOTOR 100W 100V W/BRAKE
Manufacturer
Omron
Datasheet

Specifications of R88M-WP10030S-BWS1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MWP10030SBWS1
System Design and Installation
• Connect to the case all Units inside of the case.
D Door Structure
• Construct the door of metal.
• Use a water draining structure where the door and case fit together, and leave no gaps. (Refer to the
• Use conductive packing between the door and the case, as shown in the diagrams below. Strip the
• Be careful not to let gaps be opened in the control box while tightening down screws.
H Selecting Components
3-30
diagrams below.)
paint off of the sections of the door and case that will be in contact with the conductive packing (or mask
them during painting), so that they will be electrically conductive.
This section explains the criteria for selecting the connection components required for
improving noise resistance. These criteria include capacity performance, applicable
range, and so on. For more details, contact the manufacturers directly.
Case
Door (interior view)
Control box
Door
Oil-proof packing
Conductive packing
Oil-proof packing
Cross-sectional view of A–B
Conductive packing
Door
Chapter 3

Related parts for R88M-WP10030S-BWS1