System Design and Installation
Leakage Breaker Connection Example
D Harmonic Current Countermeasures (AC Reactor)
The AC Reactor is used for suppressing harmonic currents. It suppresses sudden and quick changes in
electric currents.
In September 1994, the Ministry of International Trade and Industry established guidelines for the sup-
pression of harmonic waves emitted from home and general electric appliances. To comply with the
guidelines, appropriate measures are required to suppress the influence of harmonic waves on power
supply lines.
Select the proper AC Reactor model according to the Servo Driver that is to be used.
Note DC Reactors cannot be connected to models R88D-WT60H to R88D-WT150H, so use an AC
3-26
R88D-WTA3HL/A5HL/01HL
R88D-WT02HL
R88D-WTA3H/A5H/01H
R88D-WT02H
R88D-WT04H
R88D-WT05H/08H/10H
R88D-WT15H/20H
R88D-WT30H
R88D-WT50H
R88D-WT60H
R88D-WT75H
R88D-WT150H
DC Reactor Connection Example
Reactor instead.
Servo Drive
R88D-WTA3j to R88D-WT50H
AC power
supply side
DC Reactor
No-fuse
breaker
R88A-PX5063
R88A-PX5062
R88A-PX5071
R88A-PX5070
R88A-PX5069
R88A-PX5061
R88A-PX5060
R88A-PX5059
R88A-PX5068
3G3IV-PUZBAB40A0.265MH
3G3IV-PUZBAB60A0.18MH
3G3IV-PUZBAB90A0.12MH
Servo Driver
Model number
Surge
absorber
AC Reactor Connection Example
Reactor specifications
Leakage
breaker
1.8
3.5
0.85
1.65
3.3
4.8
8.8
14.0
26.8
40
60
90
current (A)
Rated
AC Reactor
R88D-WT60H to R88D-WT150H
Noise
filter
10.0
4.7
40.0
20.0
10.0
2.0
1.5
1.0
0.47
0.265
0.18
0.12
Inductance
Servo Driver
side
(mH)
Servo Driver
Chapter 3
DC Reactor
AC Reactor
Reactor
type