R88M-WP10030S-BWS1 Omron, R88M-WP10030S-BWS1 Datasheet - Page 236

no-image

R88M-WP10030S-BWS1

Manufacturer Part Number
R88M-WP10030S-BWS1
Description
SERVO MOTOR 100W 100V W/BRAKE
Manufacturer
Omron
Datasheet

Specifications of R88M-WP10030S-BWS1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MWP10030SBWS1
System Design and Installation
H Servo Driver Minimum Connection Resistance and External
H Wiring External Regeneration Resistance
D R88D-WTA3HL/-WTA5HL/-WT01HL/--WT02HL/-WTA3H/-WTA4H/-WTA5H/-WT01H/-W
Connect an External Regeneration Resistor between the B1 and B2 terminals.
D R88D-WT05H/-WT08H/-WT10H/-WT15H/-WT20H/-WT30H/-WT50H
Remove the short-circuit wiring between B2 and B2, and then connect an External Regeneration Resis-
tor between the B1 and B2 terminals.
D R88D-WT60H/-75H/-150H
Connect an External Regeneration Resistor or an External Regeneration Resistance Unit between the
B1 and B2 terminals.
3-42
R88D-WTA3HL to
R88D-WT01HL
R88D-WT02HL
R88D-WTA3H to
R88D-WT01H
R88D-WT02H/-WT04H
R88D-WT05H to
R88D-WT10H
R88D-WT15H
R88D-WT20H/-WT30H
R88D-WT50H
R88D-WT60H
R88D-WT75H/-WT150H
T02H/-WT04H
Regeneration Resistor Combinations
Servo Driver
Servo Driver
Servo Driver
External Regeneration Resistor
← Remove
External Regeneration Resistor
40
40
40
40
40
20
12
8
5.8
2.9
Resistance (Ω)
Connection
Minimum
Note 1. The short-circuit wiring between B2 and B3 must be
Note When using the R88A-RR22047S, connect the
1
1, 2
1
1, 2
1, 2, 3
1, 2, 3, 4, 5
1, 2, 3, 4, 5, 6
1, 2, 3, 4, 5, 6
1, 2, 3, 4, 5, 6 (or External Regeneration Resistance Unit)
1, 2, 3, 4, 5, 6 (or External Regeneration Resistance Unit)
2. When using the R88A-RR22047S, connect the
External Regeneration Resistor Combinations
thermal switch output so that the power supply will
be shut off when open.
removed.
thermal switch output so that the power supply will be
shut off when open.
Chapter 3

Related parts for R88M-WP10030S-BWS1