MOD5234-100IR NetBurner Inc, MOD5234-100IR Datasheet - Page 169

MOD5234 10/100 ETHERNET MODULE

MOD5234-100IR

Manufacturer Part Number
MOD5234-100IR
Description
MOD5234 10/100 ETHERNET MODULE
Manufacturer
NetBurner Inc
Type
Controllers & Processorsr

Specifications of MOD5234-100IR

Interface
I²C, SPI, UART
Voltage - Supply
2.5V
Mounting Type
Surface Mount
Package / Case
Module
Product
Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Data Format
-
Baud Rates
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Q4483564
MFD. If the PLL is intentionally disabled during stop mode, then after exit from stop mode, the
LOCKS flag reflects the value prior to entering stop mode once lock is regained.
7.4.6.7
If the LOLRE bit in the SYNCR is set, a loss-of-lock condition asserts reset. Reset reinitializes the
LOCK and LOCKS flags. Therefore, software must read the LOL bit in the reset status register
(RSR) to determine if a loss-of-lock caused the reset. See
(RSR).”
To exit reset in PLL mode, the reference must be present, and the PLL must achieve lock.
In external clock mode, the PLL cannot lock. Therefore, a loss-of-lock condition cannot occur, and
the LOLRE bit has no effect.
7.4.6.8
The PLL provides the ability to request an interrupt when a loss-of-lock condition occurs by
programming the LOLIRQ bit in the SYNCR. An interrupt is requested by the PLL if LOLIRQ is
set.
In external clock mode, the PLL cannot lock. Therefore, a loss-of-lock condition cannot occur, and
the LOLIRQ bit has no effect.
7.4.6.9
The LOCEN bit in the SYNCR enables the loss-of-clock detection circuit to monitor the input
clocks to the phase and frequency detector (PFD). When either the reference or feedback clock
frequency falls below the minimum frequency (see electrical specification for this value), the
loss-of-clock circuit sets the sticky LOCF bit, and non-sticky LOC bit, in the SYNSR.
In external clock mode, the loss-of-clock circuit is disabled.
7.4.6.10 Loss-of-Clock Reset
The clock module can assert a reset when a loss-of-clock or loss-of-lock occurs. When a
loss-of-clock condition is recognized, reset is asserted if the LOCRE bit in SYNCR is set. The
LOCS bit in SYNSR is cleared after reset. Therefore, the LOC bit must be read in the RSR to
determine that a loss-of-clock condition occurred. LOCRE has no effect in external clock mode.
To exit reset in PLL mode, the reference must be present, and the PLL must acquire lock.
Reset initializes the clock module registers to a known startup state as described in
“Memory Map/Register
Freescale Semiconductor
PLL Loss-of-Lock Reset
PLL Loss-of-Lock Interrupt Request
Loss-of-Clock Detection
Definition.”
MCF5235 Reference Manual, Rev. 2
Section 10.3.2, “Reset Status Register
Functional Description
Section 7.3,
7-25