MOD5234-100IR NetBurner Inc, MOD5234-100IR Datasheet - Page 671

MOD5234 10/100 ETHERNET MODULE

MOD5234-100IR

Manufacturer Part Number
MOD5234-100IR
Description
MOD5234 10/100 ETHERNET MODULE
Manufacturer
NetBurner Inc
Type
Controllers & Processorsr

Specifications of MOD5234-100IR

Interface
I²C, SPI, UART
Voltage - Supply
2.5V
Mounting Type
Surface Mount
Package / Case
Module
Product
Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Data Format
-
Baud Rates
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Q4483564
32.5.3.3.2
The operand longword data is written to the specified address or data register. A write alters all 32
register bits. A bus error response is returned if the CPU core is not halted.
Command Format:
Command Sequence
Operand Data
Result Data
32.5.3.3.3
Read data at the longword address. Address space is defined by BAAR[TT,TM]. Hardware forces
low-order address bits to zeros for word and longword accesses to ensure that word addresses are
word-aligned and longword addresses are longword-aligned.
Freescale Semiconductor
15
14
0x2
Write A/D Register (
Read Memory Location (
13
WAREG/WDREG
Figure 32-20.
12
Longword data is written into the specified address or data register. The data
is supplied most-significant word first.
Command complete status is indicated by returning 0xFFFF (with S
cleared) when the register write is complete.
Figure 32-19.
???
11
10
MCF5235 Reference Manual, Rev. 2
’NOT READY’
0x0
WAREG
MS DATA
WAREG
WAREG
BERR
XXX
9
READ
/
WDREG
/
8
D[31:16]
/
WDREG
D[15:0]
WDREG
)
7
’NOT READY’
’NOT READY’
NEXT CMD
LS DATA
Command Sequence
)
Command Format
6
0x8
5
’CMD COMPLETE’
ColdFire Background Debug Mode (BDM)
4
NEXT CMD
A/D
3
2
Register
1
0
32-27