MOD5234-100IR NetBurner Inc, MOD5234-100IR Datasheet - Page 700

MOD5234 10/100 ETHERNET MODULE

MOD5234-100IR

Manufacturer Part Number
MOD5234-100IR
Description
MOD5234 10/100 ETHERNET MODULE
Manufacturer
NetBurner Inc
Type
Controllers & Processorsr

Specifications of MOD5234-100IR

Interface
I²C, SPI, UART
Voltage - Supply
2.5V
Mounting Type
Surface Mount
Package / Case
Module
Product
Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Data Format
-
Baud Rates
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Q4483564
Debug Support
32.10.3 Development Status Register (DS)
The read-only DS register shows the status of various conditions that impact development support.
All status bits are dynamic and do not require clearing.
The DS register dynamically tracks the debug condition status even when several of them are
simultaneously asserted. For instance, if EVTI and an internal client debug request (this could be
any of the other on chip modules) are asserted at the same time, the eTPU engine will enter debug
mode and EDM will assert the bits EBP[EVTI] and CBP (internal client). Then, if CBR is asserted
the EBP bit will be cleared but the CBP bit will continue to be active since the internal client debug
request signal is still active.
32-56
1
2
3
A request to delay the processor while the eTPU is in TST will be recognized after eTPU exits TST and before the
first instruction of the thread.
One microcycle of the eTPU corresponds to two system clocks. And since the eTPU events are evaluated on every
single clock, one single microcycle may generate up to two snapshots.
If both registers are programmed to stall while the queue gets full, only the CDC can generate an overrun message.
Bits
4–3
2–0
Name
EIC
TM
Table 32-28. DC Field Descriptions (Continued)
eTPU EVTI Control.
00 EVTI assertion causes next eTPU program and data trace message to be a
01 EVTI assertion causes eTPU breakpoint generation
10 No operation
11 Reserved, reverts to 00.
Trace mode. Enables BTM, DTM, and OTM for the eTPU. One or all types of trace may be
enabled at a single time by writing to the TM field.
000 No trace enabled.
xx1 OTM
x1x DTM
1xx BTM
Note: Trace can also be enabled via the watchpoint triggers. The two enable sources are
OR’d to form the true trace enable.
synchronization message. The next CDC data trace messages are synchronized if the
next message from the eTPU is synchronized.
MCF5235 Reference Manual, Rev. 2
Description
Freescale Semiconductor

Related parts for MOD5234-100IR