HD64570 HITACHI [Hitachi Semiconductor], HD64570 Datasheet - Page 202

no-image

HD64570

Manufacturer Part Number
HD64570
Description
Serial Communications Adaptor
Manufacturer
HITACHI [Hitachi Semiconductor]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64570CP
Manufacturer:
RENESAS
Quantity:
6 500
Part Number:
HD64570CP
Manufacturer:
HIT
Quantity:
5 510
Part Number:
HD64570CP
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
HD64570CP
Quantity:
345
Part Number:
HD64570CP16
Manufacturer:
HIT
Quantity:
5 510
Part Number:
HD64570CP16
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64570F
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64570F16
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64570F16
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD64570F16
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD64570F16V
Manufacturer:
INFINEON
Quantity:
12 000
A space detected where a stop bit should be causes a framing error. The FRME bit of ST2 is
set to 1 when the received data containing a framing error is ready to be read. Here, an
interrupt request is generated (if enabled). Even if the stop bit length is 1.5 or 2 bits, only the
first bit is checked.
For details on the FRME bit, see section 5.2.11, MSCI Status Register 2 (ST2).
A framing error does not stop the reception operation. In 1/1 clock mode, start bit searching
resumes at the clock cycle following detection of the framing error. In 1/16, 1/32, or 1/64
clock mode, searching resumes after a delay of a half-bit cycle that skips invalid stop bit(s).
Once the FRME bit is set to 1 by a framing error, it cannot be cleared even if subsequent data
causes no framing error. It can be cleared only when a 1 is written to the bit position or ST2 is
reset.
Overrun error
An overrun error occurs when the receive buffer is full when new data is transferred.
When an overrun error occurs, the new data overwrites the bottom stage of the receive buffer,
erasing the previous data. At the same time, the bottom stage of the receive status FIFO is
overwritten with the status (indicating an overrun) of the new data.
The OVRN bit of ST2 is set to 1 when the overwritten data is ready to be read. Here, an
interrupt request is generated (if enabled). For details on the OVRN bit, see section 5.2.11,
MSCI Status Register 2 (ST2).
Even if an overrun error occurs, subsequent data is received normally. However, the OVRN
bit cannot be cleared even if the subsequent data causes no overrun error. It can be cleared
only when a 1 is written to the bit position or ST2 is reset.