LPC1112FHN33/203,5 NXP Semiconductors, LPC1112FHN33/203,5 Datasheet - Page 259

no-image

LPC1112FHN33/203,5

Manufacturer Part Number
LPC1112FHN33/203,5
Description
ARM Microcontrollers - MCU Cortex-M0 16kB flash up to 4 kB SRAM
Manufacturer
NXP Semiconductors
Datasheet

Specifications of LPC1112FHN33/203,5

Rohs
yes
Core
ARM Cortex M0
Processor Series
LPC1112
Data Bus Width
32 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
16 KB
Data Ram Size
4 KB
On-chip Adc
Yes
Operating Supply Voltage
1.8 V to 3.6 V
Operating Temperature Range
- 65 C to + 150 C
Package / Case
HVQFN-33
Mounting Style
SMD/SMT
Factory Pack Quantity
260
NXP Semiconductors
Table 239. Slave Receiver mode
UM10398
User manual
Status
Code
(STAT)
0x98
0xA0
Status of the I
and hardware
Previously addressed
with General Call;
DATA byte has been
received; NOT ACK
has been returned.
A STOP condition or
Repeated START
condition has been
received while still
addressed as
SLV/REC or
SLV/TRX.
2
C-bus
…continued
Application software response
To/From DAT
Read data byte or 0
Read data byte or 0
Read data byte or 1
Read data byte
No STDAT action
or
No STDAT action
or
No STDAT action
or
No STDAT action
All information provided in this document is subject to legal disclaimers.
Rev. 12 — 24 September 2012
To CON
STA STO SI
1
0
0
1
1
0
0
0
0
0
0
0
0
Chapter 15: LPC111x/LPC11Cxx I2C-bus controller
0
0
0
0
0
0
0
0
AA
0
1
0
1
0
1
0
1
Next action taken by I
Switched to not addressed SLV mode; no
recognition of own SLA or General call
address.
Switched to not addressed SLV mode;
Own SLA will be recognized; General call
address will be recognized if
ADR[0] = logic 1.
Switched to not addressed SLV mode; no
recognition of own SLA or General call
address. A START condition will be
transmitted when the bus becomes free.
Switched to not addressed SLV mode;
Own SLA will be recognized; General call
address will be recognized if
ADR[0] = logic 1. A START condition will
be transmitted when the bus becomes
free.
Switched to not addressed SLV mode; no
recognition of own SLA or General call
address.
Switched to not addressed SLV mode;
Own SLA will be recognized; General call
address will be recognized if
ADR[0] = logic 1.
Switched to not addressed SLV mode; no
recognition of own SLA or General call
address. A START condition will be
transmitted when the bus becomes free.
Switched to not addressed SLV mode;
Own SLA will be recognized; General call
address will be recognized if
ADR[0] = logic 1. A START condition will
be transmitted when the bus becomes
free.
UM10398
© NXP B.V. 2012. All rights reserved.
2
C hardware
259 of 538