User manual
26.5.8 Go <address> <mode> (UART ISP)
Table 381. UART ISP Copy RAM to flash command
Table 382. UART ISP Go command
Command
Input
Return Code CMD_SUCCESS |
Description
Example
Command
Input
Return Code CMD_SUCCESS |
Description
Example
"C 0 268467504 512<CR><LF>" copies 512 bytes from the RAM address
"G 512 T<CR><LF>" branches to address 0x0000 0200 in Thumb mode.
C
Flash Address (DST): Destination flash address where data bytes are to be
written. The destination address should be a 256 byte boundary.
RAM Address (SRC): Source RAM address from where data bytes are to be read.
Number of Bytes: Number of bytes to be written. Should be 256 | 512 | 1024 |
4096.
Remark: In parts with less than 4 kB SRAM, the number of bytes is limited to 1024
(see
SRC_ADDR_ERROR (Address not on word boundary) |
DST_ADDR_ERROR (Address not on correct boundary) |
SRC_ADDR_NOT_MAPPED |
DST_ADDR_NOT_MAPPED |
COUNT_ERROR (Byte count is not 256 | 512 | 1024 | 4096) |
SECTOR_NOT_PREPARED_FOR WRITE_OPERATION |
BUSY |
CMD_LOCKED |
PARAM_ERROR |
CODE_READ_PROTECTION_ENABLED
This command is used to program the flash memory. The "Prepare Sector(s) for
Write Operation" command should precede this command. The affected sectors are
automatically protected again once the copy command is successfully executed.
The boot block cannot be written by this command. This command is blocked when
code read protection is enabled.
0x1000 0800 to the flash address 0.
G
Address: Flash or RAM address from which the code execution is to be started.
This address should be on a word boundary.
Mode: T (Execute program in Thumb Mode).
ADDR_ERROR |
ADDR_NOT_MAPPED |
CMD_LOCKED |
PARAM_ERROR |
CODE_READ_PROTECTION_ENABLED
This command is used to execute a program residing in RAM or flash memory. It
may not be possible to return to the ISP command handler once this command is
successfully executed. This command is blocked when code read protection is
enabled. The command must be used with an address of 0x0000 0200 or greater.
All information provided in this document is subject to legal disclaimers.
Table
Rev. 12 — 24 September 2012
Chapter 26: LPC111x/LPC11Cxx Flash programming firmware
3).
UM10398
© NXP B.V. 2012. All rights reserved.
420 of 538