LPC1112FHN33/203,5 NXP Semiconductors, LPC1112FHN33/203,5 Datasheet - Page 270

no-image

LPC1112FHN33/203,5

Manufacturer Part Number
LPC1112FHN33/203,5
Description
ARM Microcontrollers - MCU Cortex-M0 16kB flash up to 4 kB SRAM
Manufacturer
NXP Semiconductors
Datasheet

Specifications of LPC1112FHN33/203,5

Rohs
yes
Core
ARM Cortex M0
Processor Series
LPC1112
Data Bus Width
32 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
16 KB
Data Ram Size
4 KB
On-chip Adc
Yes
Operating Supply Voltage
1.8 V to 3.6 V
Operating Temperature Range
- 65 C to + 150 C
Package / Case
HVQFN-33
Mounting Style
SMD/SMT
Factory Pack Quantity
260
NXP Semiconductors
UM10398
User manual
15.11.6.4 State: 0x30
15.11.6.5 State: 0x38
15.11.7.1 State: 0x40
15.11.7.2 State: 0x48
15.11.7.3 State: 0x50
15.11.7 Master Receive states
Data has been transmitted, NOT ACK received. A STOP condition will be transmitted.
Arbitration has been lost during Slave Address + Write or data. The bus has been
released and not addressed Slave mode is entered. A new START condition will be
transmitted when the bus is free again.
Previous state was State 08 or State 10. Slave Address + Read has been transmitted,
ACK has been received. Data will be received and ACK returned.
Slave Address + Read has been transmitted, NOT ACK has been received. A STOP
condition will be transmitted.
Data has been received, ACK has been returned. Data will be read from DAT. Additional
data will be received. If this is the last data byte then NOT ACK will be returned, otherwise
ACK will be returned.
6. Write 0x04 to CONSET to set the AA bit.
7. Write 0x08 to CONCLR to clear the SI flag.
8. Increment Master Transmit buffer pointer
9. Exit
1. Write 0x14 to CONSET to set the STO and AA bits.
2. Write 0x08 to CONCLR to clear the SI flag.
3. Exit
1. Write 0x24 to CONSET to set the STA and AA bits.
2. Write 0x08 to CONCLR to clear the SI flag.
3. Exit
1. Write 0x04 to CONSET to set the AA bit.
2. Write 0x08 to CONCLR to clear the SI flag.
3. Exit
1. Write 0x14 to CONSET to set the STO and AA bits.
2. Write 0x08 to CONCLR to clear the SI flag.
3. Exit
1. Read data byte from DAT into Master Receive buffer.
2. Decrement the Master data counter, skip to step 5 if not the last data byte.
3. Write 0x0C to CONCLR to clear the SI flag and the AA bit.
All information provided in this document is subject to legal disclaimers.