LPC1112FHN33/203,5 NXP Semiconductors, LPC1112FHN33/203,5 Datasheet - Page 291

no-image

LPC1112FHN33/203,5

Manufacturer Part Number
LPC1112FHN33/203,5
Description
ARM Microcontrollers - MCU Cortex-M0 16kB flash up to 4 kB SRAM
Manufacturer
NXP Semiconductors
Datasheet

Specifications of LPC1112FHN33/203,5

Rohs
yes
Core
ARM Cortex M0
Processor Series
LPC1112
Data Bus Width
32 bit
Maximum Clock Frequency
50 MHz
Program Memory Size
16 KB
Data Ram Size
4 KB
On-chip Adc
Yes
Operating Supply Voltage
1.8 V to 3.6 V
Operating Temperature Range
- 65 C to + 150 C
Package / Case
HVQFN-33
Mounting Style
SMD/SMT
Factory Pack Quantity
260
NXP Semiconductors
Table 260. CAN message interface command arbitration 2 registers (CANIF1_ARB2, address 0x4005 0034 and
Table 261. CAN message interface message control registers (CANIF1_MCTRL, address 0x4005 0038 and
UM10398
User manual
Bit
12:0
13
14
15
31:16
Bit
3:0
6:4
7
Symbol
DLC[3:0]
-
EOB
Symbol
ID[28:16]
DIR
XTD
MSGVAL
-
16.6.2.4.4 CAN message interface command arbitration 2 registers
16.6.2.4.5 CAN message interface message control registers
CANIF2_ARB2, address 0x4005 0094) bit description
CANIF2_MCTRL, address 0x4005 0098) bit description
Value
0
1
Value Description
0
1
0
1
0
1
-
Message identifier
29-bit identifier (extended frame)
11-bit identifier (standard frame)
Message direction
Direction = receive.
On TXRQST, a Remote Frame with the identifier of this Message Object is
transmitted. On reception of a Data Frame with matching identifier, that
message is stored in this Message Object.
Direction = transmit.
On TXRQST, the respective Message Object is transmitted as a Data
Frame. On reception of a Remote Frame with matching identifier, the
TXRQST bit of this Message Object is set (if RMTEN = one).
Extend identifier
The 11-bit standard identifier will be used for this message object.
The 29-bit extended identifier will be used for this message object.
Message valid
Remark: The CPU must reset the MSGVAL bit of all unused Messages
Objects during the initialization before it resets bit INIT in the CAN Control
Register. This bit must also be reset before the identifier ID28:0, the control
bits XTD, DIR, or the Data Length Code DLC3:0 are modified, or if the
Messages Object is no longer required.
The message object is ignored by the message handler.
The message object is configured and should be considered by the
message handler.
Reserved
Description
Data length code
Remark: The Data Length Code of a Message Object must be defined the
same as in all the corresponding objects with the same identifier at other
nodes. When the Message Handler stores a data frame, it will write the
DLC to the value given by the received message.
0000 - 1000 = Data frame has 0 - 8 data bytes.
1001 - 1111 = Data frame has 8 data bytes.
reserved
End of buffer
Message object belongs to a FIFO buffer and is not the last message
object of that FIFO buffer.
Single message object or last message object of a FIFO buffer.
All information provided in this document is subject to legal disclaimers.
Rev. 12 — 24 September 2012
Chapter 16: LPC111x/LPC11Cxx C_CAN controller
UM10398
© NXP B.V. 2012. All rights reserved.
Reset
value
0x00
0x00
0x00
0
0
Reset
value
0000
-
0
Access
R/W
R/W
R/W
R/W
-
291 of 538
Access
R/W
-
R/W