ALXD800EEXJ2VD AMD (ADVANCED MICRO DEVICES), ALXD800EEXJ2VD Datasheet - Page 463

no-image

ALXD800EEXJ2VD

Manufacturer Part Number
ALXD800EEXJ2VD
Description
Manufacturer
AMD (ADVANCED MICRO DEVICES)
Datasheet

Specifications of ALXD800EEXJ2VD

Operating Temperature (min)
0C
Operating Temperature (max)
85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ALXD800EEXJ2VD
Manufacturer:
AMD
Quantity:
453
Part Number:
ALXD800EEXJ2VD
Manufacturer:
AMD
Quantity:
784
Part Number:
ALXD800EEXJ2VD
Manufacturer:
AMD
Quantity:
20 000
Company:
Part Number:
ALXD800EEXJ2VD C3
Quantity:
91
Part Number:
ALXD800EEXJ2VD-C3
Manufacturer:
INTEL
Quantity:
472
Part Number:
ALXD800EEXJ2VD-C3
Manufacturer:
AMD
Quantity:
20 000
Video Input Port
6.9.5
The VIP 2.0 specification describes an 8- or 16-bit data
stream incorporating both control and data. The data/con-
trol is delivered in packets. There are two different packet
types, SAV/EAV and ancillary packets. The specification
also requires backwards compatibility to VIP 1.1 data for-
mats. Three different VIP data modes are supported: VIP
1.1 compatible mode, VIP 2.0 8-bit mode, and VIP 2.0 16-
bit mode. Differences in these modes are noted in the
descriptions of the different packet types in Section 6.9.5.1
on page 463.
6.9.5.1
The SAV/EAV packets begin with 3 bytes of preamble fol-
lowed by a Start of Active Video (SAV) status WORD.
Active data follows. The packet ends with the reception of
another 3 bytes of preamble followed by an End of Active
The status WORD provides the raster reference information:
VIP 1.1 compatible mode:
VIP 2.0 modes (8- or 16-bit data):
AMD Geode™ LX Processors Data Book
T = Task BIT
F = Field ID
V = Vertical blanking
H = Horizontal blanking
P3-0 = Reserved in VIP 1.1, New Flags in VIP 2.0
— Video Flags T, F, and V can only be changed in the
— In VIP 1.1, the Task bit is used to indicate VBI data
— P3-P0 are ignored.
— Video Flags T, F, and V are valid in the EAV and SAV
— Task bit differentiates between two video streams.
— V bit differentiates between active video and VBI data
Status WORD
Parameter
EAV code per the VIP 1.1 specification. These flags
are only captured in the EAV code.
within the video stream (T = 0 for VBI data, T = 1 for
active video). In VIP 1.1 mode, the Task bit is used in
place of the V bit to indicate VBI data.
code. Valid values must appear no later then the SAV
of the first scan line of the next active region.
These streams can be interleaved at a line or field
rate.
(V = 1 for VBI data, V = 0 for active video).
Preamble
Mode 1a,b,c - VIP Input Data
(simplified BT.656)
SAV/EAV Packets
D7
T
1
0
0
D6
1
0
0
F
Table 6-73. SAV/EAV Sequence
0 = Active video
0 = Task B
0 = Odd
0 = Active line
D5
V
1
0
0
Video (EAV) status WORD. The preamble consists of FF-
00-00. The codes FF and 00 codes are prohibited as video
samples and reserved for header and synchronization pur-
poses. The code 00 can be used within a packet to mark
an empty cycle. If a 00 code appears between the SAV and
EAV, that sample is ignore. Note that in 16-bit mode, only
the 8 LSBs are checked. If 00, the entire 16-bit WORD is
ignored. The preamble and status WORD always occurs
on bits [7:0] of the input data, even in 16-bit mode. The
active data is received on bits [7:0] in 8-bit mode and on
bits [15:0] in 16-bit mode. The Y values appear on bits [7:0]
and Cx values on bits [15:8]. Both active video and VBI
data are received in SAV/EAV packets. The format of the
SAV and EAV preamble and status WORD is shown in
Table 6-73. A sample SAV/EAV line is shown in Figure 6-40
on page 464. A full frame is shown in Figure 6-41 on page
465.
D4
H
1
0
0
— New Video Flags - The P Nibble is redefined as
[NON_INT,REPEAT,Reserved,EXT_FLAG]:
– NON_INT: 1 = non-interlaced source, 0 = inter-
– REPEAT: 1 = Repeat field in 3:2 pull-down, 0 = not
– EXT_FLAG: 1 = Extra flag byte follows this EAV, 0
laced source (not used).
a repeat field (repeat fields can be ignored by
VIP). The repeat flag must be set in the SAV for
every line in the field. The line will be saved to
memory if the repeat flag is not set. (This function
needs to be enabled in VIP Memory Offset
04h[29]).
= no extra flag byte (not implemented).
1 = Task A
1 = Even
1 = Vertical blanking
1 = Horizontal blanking
D3
P3
1
0
0
D2
P2
1
0
0
33234C
D1
P1
1
0
0
D0
P0
1
0
0
463

Related parts for ALXD800EEXJ2VD