UPD78F1152AGC-GAD-AX Renesas Electronics America, UPD78F1152AGC-GAD-AX Datasheet - Page 488

no-image

UPD78F1152AGC-GAD-AX

Manufacturer Part Number
UPD78F1152AGC-GAD-AX
Description
MCU 16BIT 78K0R/KX3 80-LQFP
Manufacturer
Renesas Electronics America
Series
78K0R/Kx3r
Datasheet

Specifications of UPD78F1152AGC-GAD-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
20MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
65
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 8x10b, D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD78F1152AGC-GAD-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
<R>
12.7.6 Procedure for processing errors that occurred during simplified I
in Figures 12-105 and 12-106.
Remark
486
Reads SDRmn register.
Reads SSRmn register.
Writes SIRmn register.
Reads SDRmn register.
Reads SSRmn register.
Writes SIRmn register.
Sets STmn bit to 1.
Creates stop condition.
Creates start condition.
Sets SSmn bit to 1.
The procedure for processing errors that occurred during simplified I
Figure 12-106. Processing Procedure in Case of Parity Error (ACK error) in Simplified I
Software Manipulation
Software Manipulation
m: Unit number (m = 0, 1), n: Channel number (n = 0, 2), mn = 02, 10
Figure 12-105. Processing Procedure in Case of Parity Error or Overrun Error
CHAPTER 12 SERIAL ARRAY UNIT
BFF = 0, and channel n is enabled to
receive data.
Error flag is cleared.
BFF = 0, and channel n is enabled to
receive data.
Error flag is cleared.
SEmn = 0, and channel n stops
operation.
SEmn = 1, and channel n is enabled to
operate.
User’s Manual U17893EJ8V0UD
Hardware Status
Hardware Status
2
C (IIC10, IIC20) communication is described
2
C (IIC10, IIC20) communication
This is to prevent an overrun error if
the next reception is completed
during error processing.
Error type is identified and the read
value is used to clear error flag.
Only error generated at the point of
reading can be cleared, by writing
the value read from the SSRmn
register to the SIRmn register
without modification.
This is to prevent an overrun error if
the next reception is completed
during error processing.
Error type is identified and the read
value is used to clear error flag.
Only error generated at the point of
reading can be cleared, by writing
the value read from the SSRmn
register to the SIRmn register
without modification.
Slave is not ready for reception
because ACK is not returned.
Therefore, a stop condition is
created, the bus is released, and
communication is started again from
the start condition. Or, a restart
condition is generated and
transmission can be redone from
address transmission.
Remark
Remark
2
C Mode

Related parts for UPD78F1152AGC-GAD-AX