UPD78F1152AGC-GAD-AX Renesas Electronics America, UPD78F1152AGC-GAD-AX Datasheet - Page 503

no-image

UPD78F1152AGC-GAD-AX

Manufacturer Part Number
UPD78F1152AGC-GAD-AX
Description
MCU 16BIT 78K0R/KX3 80-LQFP
Manufacturer
Renesas Electronics America
Series
78K0R/Kx3r
Datasheet

Specifications of UPD78F1152AGC-GAD-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
20MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
65
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 8x10b, D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD78F1152AGC-GAD-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Address: FFF52H
Symbol
IICC0
Caution The start condition is detected immediately after I
Notes 1. The IICS0 register, the STCF and IICBSY bits of the IICF0 register, and the CLD0 and DAD0
WREL0
Be sure to set this bit (1) while the SCL0 and SDA0 lines are at high level.
Condition for clearing (IICE0 = 0)
• Cleared by instruction
• Reset
The standby mode following exit from communications remains in effect until the following communications entry
conditions are met.
• After a stop condition is detected, restart is in master mode.
• An address match or extension code reception occurs after the start condition.
Condition for clearing (LREL0 = 0)
• Automatically cleared after execution
• Reset
When WREL0 is set (wait canceled) during the wait period at the ninth clock pulse in the transmission status (TRC0 =
1), the SDA0 line goes into the high impedance state (TRC0 = 0).
Condition for clearing (WREL0 = 0)
• Automatically cleared after execution
• Reset
LREL0
IICE0
IICE0
<7>
0
1
0
1
0
1
Note 2
2. The signal of this bit is invalid while IICE0 is 0.
Note 2
After reset: 00H
bits of the IICCL0 register are reset.
while the SCL0 line is at high level and the SDA0 line is at low level. Immediately after
enabling I
instruction.
Stop operation. Reset IIC status register 0 (IICS0)
Enable operation.
Normal operation
This exits from the current communications and sets standby mode. This setting is automatically cleared
to 0 after being executed.
Its uses include cases in which a locally irrelevant extension code has been received.
The SCL0 and SDA0 lines are set to high impedance.
The following flags of IIC control register 0 (IICC0) and IIC status register 0 (IICS0) are cleared to 0.
• STT0 • SPT0 • MSTS0 • EXC0 • COI0 • TRC0 • ACKD0 • STD0
Do not cancel wait
Cancel wait. This setting is automatically cleared after wait is canceled.
LREL0
<6>
Figure 13-6. Format of IIC Control Register 0 (IICC0) (1/4)
2
C to operate (IICE0 = 1), set LREL0 (1) by using a 1-bit memory manipulation
WREL0
<5>
R/W
CHAPTER 13 SERIAL INTERFACE IIC0
User’s Manual U17893EJ8V0UD
SPIE0
<4>
WTIM0
Exit from communications
<3>
I
2
C operation enable
Wait cancellation
Condition for setting (IICE0 = 1)
• Set by instruction
Condition for setting (LREL0 = 1)
• Set by instruction
Condition for setting (WREL0 = 1)
• Set by instruction
Note 1
ACKE0
<2>
. Stop internal operation.
2
C is enabled to operate (IICE0 = 1)
STT0
<1>
SPT0
<0>
501

Related parts for UPD78F1152AGC-GAD-AX