r5f71374an80fpv Renesas Electronics Corporation., r5f71374an80fpv Datasheet - Page 180

no-image

r5f71374an80fpv

Manufacturer Part Number
r5f71374an80fpv
Description
32-bit Risc Microcomputer Superh?? Risc Engine Family
Manufacturer
Renesas Electronics Corporation.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R5F71374AN80FPV
Manufacturer:
TI
Quantity:
1 001
Section 7 User Break Controller (UBC)
7.5
1. The CPU can read from or write to the UBC registers via the I bus. Accordingly, during the
2. UBC cannot monitor access to the L bus and I bus in the same channel.
3. Note on specification of sequential break:
4. When a user break and another exception occur at the same instruction, which has higher
5. Note the following exception for the above note.
6. Note the following when a user break occurs in a delay slot.
Rev. 1.00 Sep. 21, 2007 Page 154 of 1124
REJ09B0402-0100
period from executing an instruction to rewrite the UBC register till the new value is actually
rewritten, the desired user break may not occur. In order to know the timing when the UBC
register is changed, read from the last written register. Instructions after then are valid for the
newly written register value.
A condition match occurs when a B-channel match occurs in a bus cycle after an A-channel
match occurs in another bus cycle in sequential break setting. Therefore, no user break occurs
if a bus cycle in which an A-channel match and a channel B match occur simultaneously is set.
priority is determined according to the priority levels defined in table 5.1 in section 5,
Exception Handling. If an exception with higher priority occurs, the user break is not
generated.
 Pre-execution break has the highest priority.
 When a post-execution break or data access break occurs simultaneously with a re-
 When a post-execution break or data access break occurs simultaneously with a
If a post-execution break or data access break is satisfied by an instruction that generates a
CPU address error by data access, the CPU address error takes priority over the user break.
Note that the UBC condition match flag is set in this case.
If a pre-execution break is set at the delay slot instruction of the RTE instruction, the user
break does not occur until the branch destination of the RTE instruction.
execution-type exception (including pre-execution break) that has higher priority, the re-
execution-type exception is accepted, and the condition match flag is not set (see the
exception in the following note). The user break will occur and the condition match flag
will be set only after the exception source of the re-execution-type exception has been
cleared by the exception handling routine and re-execution of the same instruction has
ended.
completion-type exception (TRAPA) that has higher priority, a user break does not occur
but the condition match flag is set.
Usage Notes

Related parts for r5f71374an80fpv