HD64F2239TF20I Renesas Electronics America, HD64F2239TF20I Datasheet - Page 545

MCU 3V 384K I-TEMP 100-TQFP

HD64F2239TF20I

Manufacturer Part Number
HD64F2239TF20I
Description
MCU 3V 384K I-TEMP 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2200r
Datasheet

Specifications of HD64F2239TF20I

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
I²C, SCI, SmartCard
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
72
Program Memory Size
384KB (384K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2239TF20I
Manufacturer:
Renesas Electronics America
Quantity:
10 000
14.1.1
The overview of the IEBus is described below.
• Communications method: Half duplex asynchronous communications
• Multi-master system
• Broadcast communications function (one-to-many communications)
• Mode is selectable (three modes with different transfer speeds).
Table 14.1 Mode Types
• Access control: CSMA/CD (Carrier Sense Multiple Access with Collision Detection)
• Communications scale
Note: The communications scale of the actual system depends on the externally mounted IEBus
(1) Determination of Bus Mastership (Arbitration)
A unit connected to the IEBus performs an operation for getting the bus to control other units.
This operation is called arbitration. In arbitration, when the multiple units start transfer
simultaneously, the bus mastership is given to one unit among them.
Only one unit can get bus mastership through arbitration, so the following priority for bus
mastership is defined.
Mode
0
1
2
All units connected to the IEBus can transfer data to other units.
⎯ Group broadcast communications: Broadcast communications to group unit
⎯ General broadcast communications: Broadcast communications to all units
Priority of bus mastership is as follows.
⎯ Broadcast communications (one-to-many communications) have priority rather than
⎯ Smaller master address has priority.
⎯ Number of units: Up to 50
⎯ Cable length: Up to 150 m (when using a twisted pair cable)
normal communications (one-to-one communications).
driver/receiver characteristics and the characteristics of the cable to be used.
φ = 12 MHz
About 3.9 kbps
About 17 kbps
About 26 kbps
IEBus Communications Protocol
φ = 12.58 MHz
About 4.1 kbps
About 18 kbps
About 27 kbps
Section 14 IEBus™ Controller (IEB) [H8S/2258 Group]
Rev. 6.00 Mar. 18, 2010 Page 483 of 982
Maximum Number of
Transfer Bytes (byte/frame)
16
32
128
REJ09B0054-0600

Related parts for HD64F2239TF20I