MM912H634DM1AER2 Freescale Semiconductor, MM912H634DM1AER2 Datasheet - Page 136

no-image

MM912H634DM1AER2

Manufacturer Part Number
MM912H634DM1AER2
Description
16-bit Microcontrollers - MCU 64KS12 LIN2XLS/HS ISENSE
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MM912H634DM1AER2

Rohs
yes
Core
HCS12
Processor Series
MM912F634
Data Bus Width
16 bit
Maximum Clock Frequency
20 MHz
Program Memory Size
32 KB
Data Ram Size
2 KB
On-chip Adc
Yes
Operating Supply Voltage
5.5 V to 18 V
Operating Temperature Range
- 40 C to + 105 C
Package / Case
LQFP-48
Mounting Style
SMD/SMT
A/d Bit Size
10 bit
A/d Channels Available
15
Interface Type
SPI
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
15
Number Of Timers
1
Program Memory Type
Flash
Supply Voltage - Max
18 V
Supply Voltage - Min
5.5 V
Table 177. Main Timer Interrupt Flag 1 (TFLG1)
Note:
Functional Description and Application Information
4.18.3.3.12
Offset
126.
Freescale Semiconductor
Table 175. TIE - Register Field Descriptions (continued)
Table 178. TFLG1 - Register Field Descriptions
Reset
W
R
(126)
PR[2:0]
C[3:0]F
TCRE
Offset related to 0x0200 for blocking access and 0x300 for non blocking access within the global address space.
Field
Field
3-0
3-0
3
0xCC
7
0
0
TCRE — Timer Counter Reset Enable
1 = Enables Timer Counter reset by a successful output compare on channel 3
0 = Inhibits Timer Counter reset and counter continues to run.
Timer Prescaler Select
These three bits select the frequency of the timer prescaler clock derived from the Bus Clock as shown in
Input Capture/Output Compare Channel Flag.
1 = Input Capture or Output Compare event occurred
0 = No event (Input Capture or Output Compare event) occurred.
Main Timer Interrupt Flag 1 (TFLG1)
These flags are set when an input capture or output compare event occurs. Flag set on a
particular channel is cleared by writing a one to that corresponding CnF bit. Writing a zero
to CnF bit has no effect on its status. When TFFCA bit in TSCR register is set, a read from
an input capture or a write into an output compare channel will cause the corresponding
channel flag CnF to be cleared.
Table 176. Timer Clock Selection
PR2
0
0
0
0
1
1
1
1
6
0
0
0
0
5
PR1
0
0
1
1
0
0
1
1
NOTE
0
0
4
PR0
Description
Description
0
1
0
1
0
1
0
1
C3F
0
3
D2D Clock / 128
D2D Clock / 16
D2D Clock / 32
D2D Clock / 64
D2D Clock / 1
D2D Clock / 2
D2D Clock / 4
D2D Clock / 8
Timer Clock
Basic Timer Module - TIM (TIM16B4C)
C2F
0
2
C1F
1
0
Access: User read/write
Table
MM912F634
176.
C0F
0
0
136

Related parts for MM912H634DM1AER2