MM912H634DM1AER2 Freescale Semiconductor, MM912H634DM1AER2 Datasheet - Page 56

no-image

MM912H634DM1AER2

Manufacturer Part Number
MM912H634DM1AER2
Description
16-bit Microcontrollers - MCU 64KS12 LIN2XLS/HS ISENSE
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MM912H634DM1AER2

Rohs
yes
Core
HCS12
Processor Series
MM912F634
Data Bus Width
16 bit
Maximum Clock Frequency
20 MHz
Program Memory Size
32 KB
Data Ram Size
2 KB
On-chip Adc
Yes
Operating Supply Voltage
5.5 V to 18 V
Operating Temperature Range
- 40 C to + 105 C
Package / Case
LQFP-48
Mounting Style
SMD/SMT
A/d Bit Size
10 bit
A/d Channels Available
15
Interface Type
SPI
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
15
Number Of Timers
1
Program Memory Type
Flash
Supply Voltage - Max
18 V
Supply Voltage - Min
5.5 V
Functional Description and Application Information
4.3
The MM912F634 analog die offers three main operating modes: Normal (Run), Stop, and Sleep. In Normal mode, the device is
active and is operating under normal application conditions. In Stop mode, the voltage regulator operates with limited current
capability, the external load is expected to be reduced while in Stop mode. In Sleep mode both voltage regulators are turned off
(V
Wake-up from Stop mode is indicated by an interrupt signal. Wake-up from Sleep mode will change the MM912F634 analog die
into reset mode while the voltage regulator is turned back on.
The selection of the different modes is controlled by the Mode Control Register (MCR).
Figure 16
4.3.1
For the device power (VS1) below V
MM912F634 analog die will enter Reset mode with the condition “Power On Reset - POR”.
4.3.2
The MM912F634 analog die enters Reset mode if a reset condition occurs (POR - Power On Reset, LVR- Low Voltage Reset,
Low Voltage VDDX Reset - LVRX, WDR - Watchdog Reset, EXR - External Reset, and WUR - Wake-up Sleep Reset).
Freescale Semiconductor
DD
= V
DDX
describes how transitions are done between the different operating modes.
Modes of Operation
= 0 V).
Power Down Mode
Reset Mode
Internal Reset
External or
1)
Initial WD to be served within t
External or Internal Reset
Wake Up
WatchDog Time-Out
POR
Figure 16. Modes of Operation and Transitions
Mode
, the MM912F634 analog die is virtually in Power Down mode. Once VS1>V
Stop
Command
(POR = 1)
Power Up
Stop
WDTO
to enable Window WD
1
,
Normal
Power
Down
Reset
Mode
V
Delay (t
DD
Power Down
(V
High and Reset
SUP
Command
Sleep
<V
RST
Sleep
Mode
POR
) expired
)
and Delay (t
V
DD
Low and VSUV = 0
VTO
) expired
Wake Up
Power Down
(V
SUP
<V
Modes of Operation
POR
)
MM912F634
POR
, the
56