HD6417706F133 Renesas Electronics America, HD6417706F133 Datasheet - Page 523

IC SUPERH MPU ROMLESS 176LQFP

HD6417706F133

Manufacturer Part Number
HD6417706F133
Description
IC SUPERH MPU ROMLESS 176LQFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417706F133

Core Processor
SH-3
Core Size
32-Bit
Speed
133MHz
Connectivity
EBI/EMI, FIFO, SCI, SmartCard
Peripherals
DMA, POR, WDT
Number Of I /o
103
Program Memory Type
ROMless
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
1.75 V ~ 2.05 V
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
176-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417706F133
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706F133V
Manufacturer:
EDISON
Quantity:
2 000
Part Number:
HD6417706F133V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417706F133V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Company:
Part Number:
HD6417706F133V
Quantity:
27
Serial data transmission: Figure 16.6 shows a sample flowchart for serial transmission.
Use the following procedure for serial data transmission after enabling the SCIF for transmission.
read 1 from TDFE bit and TEND flag
trigger set number) to SCFTDR2,
Write transmit data (16 - transmit
Clear TE bit in SCSCR2 to 0
Read TDFE bit in SCSSR2
in SCSSR2, then clear to 0
Read TEND bit in SCSSR2
Set SCPDR and SCPCR
All data transmitted?
End of transmission
Start transmission
Figure 16.6 Sample Serial Transmission Flowchart
Break output?
TEND= 1?
TDFE= 1?
Yes
Yes
Yes
Yes
Section 16 Serial Communication Interface with FIFO (SCIF)
No
No
No
No
1. SCIF status check and transmit data write:
2. Serial transmission continuation procedure:
3. Break output at the end of serial
Read SCSSR2 and check that the TDFE
flag is set to 1, then write transmit data to
the SCFTDR2, read 1 from the TDFE and
TEND flags, then clear these flags to 0.
The number of transmit data bytes that can
be written is 16 - (transmit trigger set
number).
To continue serial transmission, read 1 from
the TDFE flag to confirm that writing is
possible, then write data to SCFTDR2, and
then clear the TDFE flag to 0.
transmission: To output a break in serial
transmission, set the SCPDR and SCPCR,
then clear the TE bit to 0 in the SCSCR2.
For information on SCPDR and SCPCR,
see 16.3.11, SC Port Control Register
(SCPCR), and 16.3.12, SC Port Data
Register (SCPDR).
In steps 1 and 2, it is possible to ascertain
the number of data bytes that can be
written from the number of transmit data
bytes in SCFTDR2 indicated by the upper 8
bits of the SCFDR2.
Rev. 5.00 May 29, 2006 page 473 of 698
REJ09B0146-0500

Related parts for HD6417706F133