HD6417706F133 Renesas Electronics America, HD6417706F133 Datasheet - Page 584

IC SUPERH MPU ROMLESS 176LQFP

HD6417706F133

Manufacturer Part Number
HD6417706F133
Description
IC SUPERH MPU ROMLESS 176LQFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417706F133

Core Processor
SH-3
Core Size
32-Bit
Speed
133MHz
Connectivity
EBI/EMI, FIFO, SCI, SmartCard
Peripherals
DMA, POR, WDT
Number Of I /o
103
Program Memory Type
ROMless
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
1.75 V ~ 2.05 V
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
176-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417706F133
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706F133V
Manufacturer:
EDISON
Quantity:
2 000
Part Number:
HD6417706F133V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417706F133V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Company:
Part Number:
HD6417706F133V
Quantity:
27
Section 19 A/D Converter (ADC)
Rev. 5.00 May 29, 2006 page 534 of 698
REJ09B0146-0500
Bit
5
4
3
Bit Name
ADST
MULTI
CKS
Initial Value
0
0
0
R/W
R/W
R/W
R/W
Description
A/D Start
Starts or stops A/D conversion. The ADST bit
remains set to 1 during A/D conversion. It can also
be set to 1 by external trigger input at the ADTRG
pin.
0: A/D conversion is stopped
1: 1. Single mode: A/D conversion starts; ADST is
Multi Mode
Selects single mode, multi mode or scan mode.
For further information on operation in these
modes, see section 19.6, Operation. The mode is
selected by the combination of this bit (MULTI)
and bit 5 (SCN) of ADCR.
MULTI SCN
0
0
1
1
Clock Select
Selects the A/D conversion time. Clear the ADST
bit to 0 before switching the conversion time.
0: Conversion time = 536 states (maximum)
1: Conversion time = 266 states (maximum) *
2. Multi mode: A/D conversion stauts: ADST is
3. Scan mode: A/D conversion starts and
automatically cleared to 0 when conversion
ends.
continues, cycling among the selected
channels, until ADST is cleared to 0 by
software reset, or by a transition to standby
mode.
automatically cleard to 0 when conversion
ends in all selected channels.
0
1
0
1
: Single mode
: Single mode
: Multi mode
: Scan mode
2

Related parts for HD6417706F133