EP4SE530H40I3 Altera, EP4SE530H40I3 Datasheet - Page 915

no-image

EP4SE530H40I3

Manufacturer Part Number
EP4SE530H40I3
Description
IC STRATIX IV FPGA 530K 1517HBGA
Manufacturer
Altera
Series
STRATIX® IV Er

Specifications of EP4SE530H40I3

Number Of Logic Elements/cells
531200
Number Of Labs/clbs
21248
Total Ram Bits
27376
Number Of I /o
976
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
1517-HBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SE530H40I3
Manufacturer:
ALTERA
Quantity:
325
Part Number:
EP4SE530H40I3
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SE530H40I3
Manufacturer:
ALTERA
0
Part Number:
EP4SE530H40I3N
Manufacturer:
SHARP
Quantity:
1 200
Part Number:
EP4SE530H40I3N
Manufacturer:
ALTERA
Quantity:
490
Part Number:
EP4SE530H40I3N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SE530H40I3N
Manufacturer:
ALTERA
0
Part Number:
EP4SE530H40I3N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP4SE530H40I3N
0
Chapter 5: Dynamic Reconfiguration in Stratix IV Devices
Dynamic Reconfiguration Modes Implementation
February 2011 Altera Corporation
f
1
Enabling the EyeQ Control Logic and the EyeQ Hardware
You must enable the EyeQ hardware in the ALTGX MegaWizard Plug-In Manager
and the EyeQ control block in the ALTGX_RECONIG MegaWizard Plug-In Manager.
EyeQ uses an Avalon Memory Mapped interface. For more information about this
interface, refer to the
Connections Between the ALTGX and ALTGX_RECONFIG Instances
To enable the EyeQ options, follow these steps:
1. Enable the EyeQ options in the ALTGX and ALTGX_RECONFIG MegaWizard
2. Connect the reconfig_{to/from}gxb ports between the ALTGX and
EyeQ control logic in the dynamic reconfiguration controller allows you to write to
the registers in the EyeQ hardware. Therefore, you must have a state machine in the
user design that communicates to the EyeQ control block of the ALTGX_RECONFIG
instance. You can then access the internal registers of the EyeQ hardware indirectly
through the EyeQ control logic.
Altera recommends having an input pattern generator and checker to monitor the
BER of the received data.
EyeQ hardware is available for each transceiver channel in the receiver data path.
Select the Analog Controls option in the Reconfiguration Settings screen of the
ALTGX MegaWizard Plug-In Manager to enable the EyeQ hardware.
EyeQ control logic is available in the dynamic reconfiguration controller. Select the
EyeQ control option in the ALTGX_RECONFIG MegaWizard Plug-In Manager to
enable the EyeQ control logic.
Plug-In Managers as explained in
Hardware” on page
ALTGX_RECONFIG instances.
Avalon Interface
5–69.
Specification.
“Enabling the EyeQ Control Logic and the EyeQ
Stratix IV Device Handbook Volume 2: Transceivers
5–69

Related parts for EP4SE530H40I3