EP4SE530H40I3 Altera, EP4SE530H40I3 Datasheet - Page 924

no-image

EP4SE530H40I3

Manufacturer Part Number
EP4SE530H40I3
Description
IC STRATIX IV FPGA 530K 1517HBGA
Manufacturer
Altera
Series
STRATIX® IV Er

Specifications of EP4SE530H40I3

Number Of Logic Elements/cells
531200
Number Of Labs/clbs
21248
Total Ram Bits
27376
Number Of I /o
976
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
1517-HBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SE530H40I3
Manufacturer:
ALTERA
Quantity:
325
Part Number:
EP4SE530H40I3
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SE530H40I3
Manufacturer:
ALTERA
0
Part Number:
EP4SE530H40I3N
Manufacturer:
SHARP
Quantity:
1 200
Part Number:
EP4SE530H40I3N
Manufacturer:
ALTERA
Quantity:
490
Part Number:
EP4SE530H40I3N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SE530H40I3N
Manufacturer:
ALTERA
0
Part Number:
EP4SE530H40I3N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP4SE530H40I3N
0
5–78
Table 5–16. Dynamic Reconfiguration Controller Port List (ALTGX_RECONFIG Instance) (Part 3 of 13)
Stratix IV Device Handbook Volume 2: Transceivers
reconfig_fromgxb
(continued)
reconfig_togxb[3:0]
FPGA Fabric and ALTGX_RECONFIG Interface Signals
write_all
Port Name
Output
Output
Input/
Input
Input
To connect the reconfig_fromgxb port between the
ALTGX_RECONFIG instance and multiple ALTGX instances, follow
these rules:
The Quartus II Fitter produces an error if the dynamic
reconfiguration option is enabled in the ALTGX instance but the
reconfig_fromgxb and reconfig_togxb ports are not
connected to the ALTGX_RECONFIG instance.
For more information, refer to
ALTGX_RECONFIG Instances” on page
An input port of the ALTGX instance and an output port of the
ALTGX_RECONFIG instance. You must connect the
reconfig_togxb[3:0] input port of every ALTGX instance
controlled by the dynamic reconfiguration controller to the
reconfig_togxb[3:0] output port of the ALTGX_RECONFIG
instance.
The width of this port is always fixed to 3 bits.
For more information, refer to
ALTGX_RECONFIG Instances” on page
Assert this signal for one reconfig_clk clock cycle to initiate a
write transaction from the ALTGX_RECONFIG instance to the
ALTGX instance.
You can use this signal in two ways for .mif-based modes:
Connect the reconfig_fromgxb[16:0] of ALTGX Instance 1 to
the reconfig_fromgxb[16:0] of the ALTGX_RECONFIG
instance. Connect the reconfig_fromgxb[] port of the next
ALTGX instance to the next available bits of the
ALTGX_RECONFIG instance, and so on.
Connect the reconfig_fromgxb port of the ALTGX instance,
which has the highest What is the starting channel number?
option, to the MSB of the reconfig_fromgxb port of the
ALTGX_RECONFIG instance.
Continuous write operation—Select the Enable continuous
write of all the words needed for reconfiguration option to
pulse the write_all signal only once for writing a whole .mif.
The What is the read latency of the MIF contents option is
available for selection in this case only. Enter the desired latency
in terms of the reconfig_clk cycles.
Regular write operation—When the Enable continuous write of
all the words needed for reconfiguration option is disabled,
every word of the .mif requires its own write cycle.
Chapter 5: Dynamic Reconfiguration in Stratix IV Devices
Description
Dynamic Reconfiguration Controller Port List
“Connecting the ALTGX and
“Connecting the ALTGX and
February 2011 Altera Corporation
5–11.
5–11.
(Note
3),
(4)

Related parts for EP4SE530H40I3