Section 6 Power-Down Modes
6.2.4
STBCR4 is a readable/writable 8-bit register used to select whether or not individual modules
operate in power-down mode. STBCR4 is initialized (to H'00) by a power-on reset, but retains its
previous value after a manual reset or a period in the standby mode. Only byte access is valid.
Rev. 4.00 Sep. 14, 2005 Page 170 of 982
REJ09B0023-0400
Bit
7
6
5
4
3
2
1, 0
Standby Control Register 4 (STBCR4)
Bit Name
MSTP46
MSTP45
MSTP44
MSTP43
MSTP42
Initial
Value
0
0
0
0
0
0
All 0
R/W
R
R/W
R/W
R/W
R/W
R/W
R
Description
Reserved
This bit is always read as 0. The write value should
always be 0.
Module Stop 46
0: The USB module stops.
1: Supply of the clock to the USB is started.
Module Stop 45
When the MSTP45 bit is set to 1, supply of the clock
to the MTU stops.
0: The MTU runs.
1: Supply of the clock to the MTU stops.
Module Stop 44
When the MSTP44 bit is set to 1, supply of the clock
to the POE stops.
0: The POE runs.
1: Supply of the clock to the POE stops.
Module Stop 43
When the MSTP43 bit is set to 1, supply of the clock
to the CMT1 stops.
0: The CMT1 runs.
1: Supply of the clock to the CMT1 stops.
Module Stop 42
When the MSTP42 bit is set to 1, supply of the clock
to the IIC2 stops.
0: The IIC2 runs.
1: Supply of the clock to the IIC2 stops.
Reserved
These bits are always read as 0. The write value
should always be 0.