HD6417641 RENESAS [Renesas Technology Corp], HD6417641 Datasheet - Page 645

no-image

HD6417641

Manufacturer Part Number
HD6417641
Description
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet
Section 18 Multi-Function Timer Pulse Unit (MTU)
Outline of Complementary PWM Mode Operation
In complementary PWM mode, 6-phase PWM output is possible. Figure 18.34 illustrates counter
operation in complementary PWM mode, and figure 18.35 shows an example of complementary
PWM mode operation.
Counter Operation: In complementary PWM mode, three counters−TCNT_3, TCNT_4, and
TCNTS−perform up/down-count operations.
TCNT_3 is automatically initialized to the value set in TDDR when complementary PWM mode
is selected and the CST bit in TSTR is 0.
When the CST bit is set to 1, TCNT_3 counts up to the value set in TGRA_3, then switches to
down-counting when it matches TGRA_3. When the TCNT3 value matches TDDR, the counter
switches to up-counting, and the operation is repeated in this way.
TCNT_4 is initialized to H'0000.
When the CST bit is set to 1, TCNT4 counts up in synchronization with TCNT_3, and switches to
down-counting when it matches TCDR. On reaching H'0000, TCNT4 switches to up-counting,
and the operation is repeated in this way.
TCNTS is a read-only counter. It need not be initialized.
When TCNT_3 matches TCDR during TCNT_3 and TCNT_4 up/down-counting, down-counting
is started, and when TCNTS matches TCDR, the operation switches to up-counting. When
TCNTS matches TGRA_3, it is cleared to H'0000.
When TCNT_4 matches TDDR during TCNT_3 and TCNT_4 down-counting, up-counting is
started, and when TCNTS matches TDDR, the operation switches to down-counting. When
TCNTS reaches H'0000, it is set with the value in TGRA_3.
TCNTS is compared with the compare register and temporary register in which the PWM duty is
set during the count operation only.
Rev. 4.00 Sep. 14, 2005 Page 595 of 982
REJ09B0023-0400

Related parts for HD6417641