16.4.3
In master receive mode, the master device outputs the receive clock, receives data from the slave
device, and returns an acknowledge signal. For master receive mode operation timing, refer to
figures 16.7 and 16.8. The reception procedure and operations in master receive mode are shown
below.
1. Clear the TEND bit in ICSR to 0, then clear the TRS bit in ICCR1 to 0 to switch from master
2. When ICDRR is read (dummy data read), reception is started, and the receive clock is output,
3. After the reception of first frame data is completed, the RDRF bit in ICST is set to 1 at the rise
4. The continuous reception is performed by reading ICDRR every time RDRF is set. If eighth
5. If next frame is the last receive data, set the RCVD bit in ICCR1 to 1 before reading ICDRR.
6. When the RDRF bit is set to 1 at rise of the ninth receive clock pulse, issue the stage condition.
7. When the STOP bit in ICSR is set to 1, read ICDRR. Then clear the RCVD bit to 0.
8. The operation returns to the slave receive mode.
Note: Set the RCVD bit in ICCR1 to dummy-read ICDRR to receive only one byte.
transmit mode to master receive mode. Then, clear the TDRE bit to 0.
and data received, in synchronization with the internal clock. The master device outputs the
level specified by ACKBT in ICIER to SDA, at the ninth receive clock pulse.
of ninth receive clock pulse. At this time, the receive data is read by reading ICDRR, and
RDRF is cleared to 0.
receive clock pulse falls after reading ICDRR by the other processing while RDRF is 1, SCL is
fixed low until ICDRR is read.
This enables the issuance of the stop condition after the next reception.
Master Receive Operation
Rev. 4.00 Sep. 14, 2005 Page 491 of 982
Section 16 I
2
C Bus Interface 2 (IIC2)
REJ09B0023-0400