HD6417641 RENESAS [Renesas Technology Corp], HD6417641 Datasheet - Page 773

no-image

HD6417641

Manufacturer Part Number
HD6417641
Description
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet
19.4.2
In asynchronous mode, each transmitted or received character begins with a start bit and ends with
a stop bit. Serial communication is synchronized one character at a time.
The transmitting and receiving sections of the SCIF are independent, so full duplex
communication is possible. The transmitter and receiver are 16-byte FIFO buffered, so data can be
written and read while transmitting and receiving are in progress, enabling continuous transmitting
and receiving.
Figure 19.2 shows the general format of asynchronous serial communication. In asynchronous
serial communication, the communication line is normally held in the mark (high) state. The SCIF
monitors the line and starts serial communication when the line goes to the space (low) state,
indicating a start bit. One serial character consists of a start bit (low), data (LSB first), parity bit
(high or low), and stop bit (high), in that order.
When receiving in asynchronous mode, the SCIF synchronizes at the falling edge of the start bit.
The SCIF samples each data bit on the eighth pulse of a clock with a frequency 16 times the bit
rate. Receive data is latched at the center of each bit.
Serial
data
Operation in Asynchronous Mode
Figure 19.2 Example of Data Format in Asynchronous Communication
1
Start
bit
1 bit
0
LSB
D0
(8-Bit Data with Parity and Two Stop Bits)
One unit of transfer data (character or frame)
D1
D2
Transmit/receive data
D3
7 or 8 bits
Section 19 Serial Communication Interface with FIFO (SCIF)
D4
D5
D6
MSB
D7
Rev. 4.00 Sep. 14, 2005 Page 723 of 982
Parity
bit
1 bit or
none
0/1
Stop bit
1
1 or 2 bits
1
(mark state)
Idle state
REJ09B0023-0400