22.1.7
PEMTURWER is a 16-bit readable/writable register that allows access of the MTU registers.
PEMTURWER is initialized to H'0001 by a power-on reset, and it is not initialized by a manual
reset, in standby mode, or in sleep mode.
Bit
15 to 1
0
Port E MTU R/W Enable Register (PEMTURWER)
Bit Name
MTURWE
Initial
Value
All 0
1
R/W
R
R/W
Description
Reserved
These bits are always read as 0. The write value should
always be 0.
MTURWE allows access of the MTU registers. For
details, see section 18, Multi-Function Timer Pulse Unit
(MTU).
0: Disables access of the MTU registers.
1: Enables access of the MTU registers.
Rev. 4.00 Sep. 14, 2005 Page 833 of 982