HD6417641 RENESAS [Renesas Technology Corp], HD6417641 Datasheet - Page 692

no-image

HD6417641

Manufacturer Part Number
HD6417641
Description
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet
Section 18 Multi-Function Timer Pulse Unit (MTU)
18.8.3
If an error occurs during MTU operation, MTU output should be cut by the system. Cutoff is
performed by switching the pin output to port output with the PFC and outputting the inverse of
the active level. For large-current pins, output can also be cut by hardware, using port output
enable (POE). The pin initialization procedures for re-setting due to an error during operation, etc.,
and the procedures for restarting in a different mode after re-setting, are shown below.
The MTU has six operating modes, as stated above. There are thus 36 mode transition
combinations, but some transitions are not available with certain channel and mode combinations.
Possible mode transition combinations are shown in table 18.43.
Table 18.43 Mode Transition Combinations
[Legend]
Normal: Normal mode
PWM1: PWM mode 1
PWM2: PWM mode 2
PCM:
CPWM: Complementary PWM mode
RPWM: Reset-synchronous PWM mode
The above abbreviations are used in some places in following descriptions.
Rev. 4.00 Sep. 14, 2005 Page 642 of 982
REJ09B0023-0400
Before
Normal
PWM1
PWM2
PCM
CPWM
RPWM
Phase counting modes 1 to 4
Operation in Case of Re-Setting Due to Error During Operation, etc.
Normal
(1)
(7)
(13)
(17)
(21)
(26)
PWM1
(2)
(8)
(14)
(18)
(22)
(27)
PWM2
(3)
(9)
(15)
(19)
None
None
After
PCM
(4)
(10)
(16)
(20)
None
None
None
None
CPWM
(5)
(11)
(23) (24)
(28)
RPWM
(6)
(12)
None
None
(25)
(29)

Related parts for HD6417641