Data Array: Holds a 16-byte instruction or data. Entries are registered in the cache in line units
(16 bytes). The data array is not initialized by a power-on or manual reset, standby mode, module
standby mode, and sleep mode.
LRU: With the 4-way set associative system, up to four instructions or data with the same entry
address (address bits 11 to 4) can be registered in the cache. When an entry is registered, LRU
shows which of the four ways it is recorded in. There are six LRU bits, controlled by hardware. A
least-recently-used (LRU) algorithm is used to select the way that has been least recently accessed.
Six LRU bits indicate the way to be replaced in case of a cache miss.
The relationship between LRU and way replacement is shown is table 7.3 when the cache lock
function is not used 1 concerning the case where the cache lock function is used, see section 7.2.2,
Cache Control Register 2 (CCR2). If a bit pattern other than those listed in table 7.3 is set in the
LRU bits by software, the cache will not function correctly. When modifying the LRU bits by
software, set one of the patterns listed in table 7.3.
The LRU bits are initialized to 000000 by a power-on reset and retaining the previous value by a
manual reset, standby mode, module standby mode, and sleep mode.
Table 7.3
LRU (Bits 5 to 0)
000000, 000100, 010100, 100000, 110000, 110100
000001, 000011, 001011, 100001, 101001, 101011
000110, 000111, 001111, 010110, 011110, 011111
111000, 111001, 111011, 111100, 111110, 111111
LRU and Way Replacement
Way to be Replaced
3
2
1
0
Rev. 4.00 Sep. 14, 2005 Page 181 of 982