Section 18 Multi-Function Timer Pulse Unit (MTU)
When compare match is selected as the TCNT clearing source, the TCNT counter for the relevant
channel performs periodic count operation. The TGR register for setting the period is designated
as an output compare register, and counter clearing by compare match is selected by means of bits
CCLR0 to CCLR2 in TCR. After the settings have been made, TCNT starts up-count operation as
a periodic counter when the corresponding bit in TSTR is set to 1. When the count value matches
the value in TGR, the TGF bit in TSR is set to 1 and TCNT is cleared to H'0000.
If the value of the corresponding TGIE bit in TIER is 1 at this point, the TPU requests an interrupt.
After a compare match, TCNT starts counting up again from H'0000.
Figure 18.5 illustrates periodic counter operation.
• Waveform Output by Compare Match
The MTU can perform 0, 1, or toggle output from the corresponding output pin using compare
match.
Rev. 4.00 Sep. 14, 2005 Page 564 of 982
REJ09B0023-0400
H'FFFF
H'0000
CST bit
TCFV
TGR
H'0000
CST bit
TGF
TCNT value
TCNT value
Figure 18.4 Free-Running Counter Operation
Figure 18.5 Periodic Counter Operation