HD6417641 RENESAS [Renesas Technology Corp], HD6417641 Datasheet - Page 602

no-image

HD6417641

Manufacturer Part Number
HD6417641
Description
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet
Section 18 Multi-Function Timer Pulse Unit (MTU)
Rev. 4.00 Sep. 14, 2005 Page 552 of 982
REJ09B0023-0400
Bit
2
1
Bit Name
TGFC
TGFB
Initial
value
0
0
R/W
R/(W) Input Capture/Output Compare Flag C
R/(W) Input Capture/Output Compare Flag B
Description
Status flag that indicates the occurrence of TGRC input
capture or compare match in channels 0, 3, and 4. Only
0 can be written, for flag clearing. In channels 1 and 2,
bit 2 is reserved. It is always read as 0, and should only
be written with 0.
[Setting conditions]
[Clearing condition]
Status flag that indicates the occurrence of TGRB input
capture or compare match. Only 0 can be written, for
flag clearing.
[Setting conditions]
[Clearing condition]
When TCNT = TGRC and TGRC is functioning as
output compare register
When TCNT value is transferred to TGRC by input
capture signal and TGRC is functioning as input
capture register
When 0 is written to TGFC after reading TGFC = 1
When TCNT = TGRB and TGRB is functioning as
output compare register
When TCNT value is transferred to TGRB by input
capture signal and TGRB is functioning as input
capture register
When 0 is written to TGFB after reading TGFB = 1