PM5381-BI PMC-Sierra, Inc., PM5381-BI Datasheet - Page 273

no-image

PM5381-BI

Manufacturer Part Number
PM5381-BI
Description
ATM UNI, Single Channel ATM PHY Interface for 2488.32Mbps
Manufacturer
PMC-Sierra, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PM5381-BI-P
Quantity:
119
Part Number:
PM5381-BI-P
Quantity:
6
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-2000489, Issue 4
PLOPE
PAISE
PLOPCE
PAISCE
The path loss of pointer interrupt enable (PLOPE) bit controls the activation of the interrupt
(INTB) output. When PLOPE is set to logic 1, the PLOPI pending interrupt will assert the
interrupt (INTB) output. When PLOPE is set to logic 0, the PLOPI pending interrupt will not
assert the interrupt (INTB) output.
This bit is only valid for RHPP STS-1/STM0 #1 except in the XCONNECT mode of
operation.
The path alarm indication signal interrupt enable (PAISE) bit controls the activation of the
interrupt (INTB) output. When PAISE is set to logic 1, the PAISI pending interrupt will
assert the interrupt (INTB) output. When PAISE is set to logic 0, the PAISI pending interrupt
will not assert the interrupt (INTB) output.
This bit is only valid for RHPP STS-1/STM0 #1 except in the XCONNECT mode of
operation.
The path loss of pointer concatenation interrupt enable (PLOPCE) bit controls the activation
of the interrupt (INTB) output. When PLOPCE is set to logic 1, the PLOPCI pending
interrupt will assert the interrupt (INTB) output. When PLOPCE is set to logic 0, the
PLOPCI pending interrupt will not assert the interrupt (INTB) output.
This bit is only valid for RHPP STS-1/STM0 #2-48 except in the XCONNECT mode of
operation.
The path concatenation alarm indication signal interrupt enable (PAISCE) bit controls the
activation of the interrupt (INTB) output. When PAISCE is set to logic 1, the PAISCI
pending interrupt will assert the interrupt (INTB) output. When PAISCE is set to logic 0, the
PAISCI pending interrupt will not assert the interrupt (INTB) output.
This bit is only valid for RHPP STS-1/STM0 #2-48 except in the XCONNECT mode of
operation.
S/UNI-2488 Telecom Standard Product Datasheet
Released
273