UPD78F1506GF-GAT-AX Renesas Electronics America, UPD78F1506GF-GAT-AX Datasheet - Page 299

no-image

UPD78F1506GF-GAT-AX

Manufacturer Part Number
UPD78F1506GF-GAT-AX
Description
MCU 16BIT 78K0R/LX3 128-LQFP
Manufacturer
Renesas Electronics America
Series
78K0R/Lx3r
Datasheet

Specifications of UPD78F1506GF-GAT-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
20MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
DMA, LCD, LVD, POR, PWM, WDT
Number Of I /o
78
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 12x12b, D/A 2x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
78K0R/Lx3
R01UH0004EJ0401 Rev.4.01
Jul 2, 2010
(3) Operation of TOpq pin in combination operation mode (TOMpq = 1)
(b) When operation starts with TOMpq = 1 setting (Combination operation mode (PWM output))
(a) When TOLpq setting has been changed during timer operation
Remarks 1. Set:
When TOMpq = 1, the active level is determined by TOLpq setting.
When the TOLpq setting has been changed during timer operation, the setting becomes valid at the generation
timing of TOpq change condition. Rewriting TOLpq does not change the output level of TOpq.
The following figure shows the operation when the value of TOLpq has been changed during timer operation
(TOMpq = 1).
Default level, TOLpq setting
TOpq = 0, TOLpq = 0
TOpq = 1, TOLpq = 0
TOpq = 0, TOLpq = 1
TOpq = 1, TOLpq = 1
2. pq: Unit number + Channel number (only for channels provided with timer I/O pins)
Figure 6-30. Operation when TOLpq Has Been Changed during Timer Operation
78K0R/LF3: pq = 00 to 04, 07
78K0R/LG3: pq = 00 to 07
78K0R/LH3: pq = 00 to 07, 10 to 13
Internal reset signal
Reset:
Internal set signal
(Active high)
(Active high)
(Active low)
(Active low)
Figure 6-29. TOpq Pin Output Status at PWM Output (TOMpq = 1)
TOEpq
TOpq pin
The output signal of TOpq pin changes from active level to inactive level.
The output signal of TOpq pin changes from inactive level to active level.
TOLpq
Port output is enabled
Dependent on TOpq setting
Hi-Z
Hi-Z
Hi-Z
Hi-Z
Set
TOpq does not change
No change
Reset
TOpq pin transition
Dependent on TOLpq setting
Set
Set/reset signals are inverted
CHAPTER 6 TIMER ARRAY UNIT
Reset
Set
299

Related parts for UPD78F1506GF-GAT-AX