UPD78F1506GF-GAT-AX Renesas Electronics America, UPD78F1506GF-GAT-AX Datasheet - Page 355

no-image

UPD78F1506GF-GAT-AX

Manufacturer Part Number
UPD78F1506GF-GAT-AX
Description
MCU 16BIT 78K0R/LX3 128-LQFP
Manufacturer
Renesas Electronics America
Series
78K0R/Lx3r
Datasheet

Specifications of UPD78F1506GF-GAT-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
20MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
DMA, LCD, LVD, POR, PWM, WDT
Number Of I /o
78
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 12x12b, D/A 2x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
78K0R/Lx3
R01UH0004EJ0401 Rev.4.01
Jul 2, 2010
Address: F00F0H
(1) Peripheral enable register 0 (PER0)
(2) Real-time counter control register 0 (RTCC0)
Symbol
PER0
PER0 is used to enable or disable use of each peripheral hardware macro. Clock supply to a hardware macro that
is not used is stopped in order to reduce the power consumption and noise.
When the real-time counter is used, be sure to set bit 7 (RTCEN) of this register to 1.
PER0 can be set by a 1-bit or 8-bit memory manipulation instruction.
Reset signal generation clears this register to 00H.
The RTCC0 register is an 8-bit register that is used to start or stop the real-time counter operation, control the
RTCCL and RTC1HZ pins, and set a 12- or 24-hour system and the constant-period interrupt function.
RTCC0 can be set by a 1-bit or 8-bit memory manipulation instruction.
Reset signal generation clears this register to 00H.
RTCEN
RTCEN
Notes 1.
Cautions 1. When using the real-time counter, first set RTCEN to 1, while oscillation of the
<7>
0
1
After reset: 00H
2.
Stops supply of input clock.
• SFR used by the real-time counter (RTC) cannot be written.
• The real-time counter (RTC) is in the reset status.
Supplies input clock.
• SFR used by the real-time counter (RTC) can be read/written.
2. Clock supply to peripheral functions except the real-time counter can be stopped in
78K0R/LG3, 78K0R/LH3 only
By using RTCEN, can supply and stop the clock that is used when accessing the real-time
counter (RTC) from the CPU. RTCEN cannot control supply of the operating clock (f
RTC.
DACEN
Figure 7-2. Format of Peripheral Enable Register 0 (PER0)
<6>
subsystem clock (f
real-time counter is ignored, and, even if the register is read, only the default value is
read.
the HALT mode when operating on the subsystem clock by setting RTCLPC of the
operation speed mode control register (OSMC) to 1. In this case, set RTCEN to 1 and
bits 0 to 6 of PER0 to 0.
R/W
ADCEN
<5>
Control of real-time counter (RTC) input clock
SUB
IICAEN
) is stable. If RTCEN = 0, writing to a control register of the
<4>
Note1
SAU1EN
<3>
CHAPTER 7 REAL-TIME COUNTER
SAU0EN
<2>
Note2
TAU1EN
<1>
TAU0EN
<0>
SUB
) to
355