UPD78F1506GF-GAT-AX Renesas Electronics America, UPD78F1506GF-GAT-AX Datasheet - Page 357

no-image

UPD78F1506GF-GAT-AX

Manufacturer Part Number
UPD78F1506GF-GAT-AX
Description
MCU 16BIT 78K0R/LX3 128-LQFP
Manufacturer
Renesas Electronics America
Series
78K0R/Lx3r
Datasheet

Specifications of UPD78F1506GF-GAT-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
20MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
DMA, LCD, LVD, POR, PWM, WDT
Number Of I /o
78
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 12x12b, D/A 2x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
78K0R/Lx3
R01UH0004EJ0401 Rev.4.01
Jul 2, 2010
Address: FFF9EH
(3) Real-time counter control register 1 (RTCC1)
RTCC1
Symbol
The RTCC1 register is an 8-bit register that is used to control the alarm interrupt function and the wait time of the
counter.
RTCC1 can be set by a 1-bit or 8-bit memory manipulation instruction.
Reset signal generation clears this register to 00H.
When setting a value to the WALE bit while the counter operates (RTCE = 1) and WALIE = 1, rewrite the WALE bit
after disabling interrupt servicing INTRTC by using the interrupt mask flag register. Furthermore, clear the WAFG
and RTCIF flags after rewriting the WALE bit. When setting each alarm register (WALIE flag of RTCC1, the
ALARMWM register, the ALARMWH register, and the ALARMWW register), set match operation to be invalid (“0”)
for the WALE bit.
This is a status flag that indicates detection of matching with the alarm. It is valid only when WALE = 1 and is set to
“1” one clock (32.768 kHz) after matching of the alarm is detected. This flag is cleared when “0” is written to it.
Writing “1” to it is invalid.
WALIE
WAFG
WALE
WALE
<7>
0
1
0
1
0
1
After reset: 00H
Figure 7-4. Format of Real-Time Counter Control Register 1 (RTCC1) (1/2)
Match operation is invalid.
Match operation is valid.
Does not generate interrupt on matching of alarm.
Generates interrupt on matching of alarm.
Alarm mismatch
Detection of matching of alarm
WALIE
<6>
R/W
5
0
Control of alarm interrupt (INTRTC) function operation
WAFG
<4>
Alarm detection status flag
Alarm operation control
RIFG
<3>
CHAPTER 7 REAL-TIME COUNTER
2
0
RWST
<1>
RWAIT
<0>
357