Specifications of UPD78F1506GF-GAT-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
20MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
DMA, LCD, LVD, POR, PWM, WDT
Number Of I /o
78
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 12x12b, D/A 2x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
78K0R/Lx3
R01UH0004EJ0401 Rev.4.01
Jul 2, 2010
(Essential)
(Selective)
(Selective)
(Selective)
(Selective)
(Selective)
(Essential)
(Selective)
(Essential)
(Essential)
(Essential)
Changing setting of SOEm register
Changing setting of SPSm register
Changing setting of SMRmn register
Changing setting of SDRmn register
Changing setting of SCRmn register
Changing setting of SOm register
Starting setting for resumption
Figure 14-35. Procedure for Resuming Master Reception
Starting communication
Writing to SSm register
Clearing error flag
Port manipulation
Port manipulation
Enable clock output of the target channel
by setting a port register and a port mode
register.
Disable clock output of the target
channel by setting a port register and a
port mode register.
Change the setting if an incorrect division
ratio of the operation clock is set.
Change the setting if an incorrect
transfer baud rate is set.
Change the setting if the setting of the
SMRmn register is incorrect.
Change the setting if the setting of the
SCRmn register is incorrect.
Manipulate the CKOmn bit and set a
clock output level.
Clear the SOEm register to 0 and stop
data output of the target channel.
Cleared by using SIRmn register if FEF,
PEF, or OVF flag remains set.
Set the SSmn bit of the target channel to
1 to set SEmn = 1.
Sets dummy data to the SIOp register
(bits 7 to 0 of the SDRmn register) and
start communication.
CHAPTER 14 SERIAL ARRAY UNIT