R5F2L3AAANFP#U1 Renesas Electronics America, R5F2L3AAANFP#U1 Datasheet - Page 498

MCU FLASH 96+4KB 100LQFP

R5F2L3AAANFP#U1

Manufacturer Part Number
R5F2L3AAANFP#U1
Description
MCU FLASH 96+4KB 100LQFP
Manufacturer
Renesas Electronics America
Series
R8C/Lx/3AAr
Datasheet

Specifications of R5F2L3AAANFP#U1

Core Processor
R8C
Core Size
16/32-Bit
Speed
20MHz
Connectivity
I²C, LIN, SIO, SSU, UART/USART
Peripherals
LCD, POR, PWM, Voltage Detect, WDT
Number Of I /o
88
Program Memory Size
96KB (96K x 8)
Program Memory Type
FLASH
Ram Size
10K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 20x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 85°C
Package / Case
100-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
R5F2L3AAANFP#U1
Manufacturer:
Renesas Electronics America
Quantity:
10 000
R8C/L35A Group, R8C/L36A Group, R8C/L38A Group, R8C/L3AA Group,
R8C/L35B Group, R8C/L36B Group, R8C/L38B Group, R8C/L3AB Group
REJ09B0441-0100 Rev.1.00
Page 461 of 802
Figure 22.6
Figure 22.7
22.4.2
22.4.3
Figure 22.6 shows a Procedure Example for Setting Input Capture Operation.
The rising edge, falling edge, or both edges can be selected for input-capture input by setting the TRGIOR
register.
Figure 22.7 shows the Input-Capture Input Signal Timing.
The pulse width of input-capture input signals should be 1.5 f1 or more for a single edge and 2.5 f1 or more for
both edges.
Select input-capture input
Procedure Example for Setting Input Capture Operation
Input Capture Signal Timing
Input capture operation
Count operation starts
Input capture signal
Input selection
Procedure Example for Setting Input Capture Operation
Input-Capture Input Signal Timing
TRGGRj register
(internal signal)
TRGIOj input
TRG register
f1
Oct 30, 2009
j = A or B
(1)
(2)
(1) Use the TRGIOR register to set TRGGRj (j = A or B) as an input
(2) Set the TSTART bit in the TRGMR register to 1 to start the count
capture register and select the input edge of input capture signals
from the following three: the rising edge, falling edge, or both edges.
operation of the TRG register.
N